Wearable and Multiplexed Biosensors based on Oxide Field‐Effect Transistors
Small Methods · 2024
DOI: 10.1002/smtd.202400781 ↗Kurz gefasst
Fachartikel in der Zeitschrift Small Methods, 2024. Verfasst von Huihui Ren und 13 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials and Engineering, Zhejiang University, Hangzhou, 310027, China. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Biosensing Techniques, Transistors, Electronic. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Westlake Institute for Optoelectronic.
Abstract (Originalsprache)
Wearable sensors designed for continuous, non‐invasive monitoring of physicochemical signals are important for portable healthcare. Oxide field‐effect transistor (FET)‐type biosensors provide high sensitivity and scalability. However, they face challenges in mechanical flexibility, multiplexed sensing of different modules, and the absence of integrated on‐site signal processing and wireless transmission functionalities for wearable sensing. In this work, a fully integrated wearable oxide FET‐based biosensor array is developed to facilitate the multiplexed and simultaneous measurement of ion concentrations (H + , Na + , K + ) and temperature. The FET‐sensor array is achieved by utilizing a solution‐processed ultrathin (≈6 nm thick) In 2 O 3 active channel layer, exhibiting high compatibility with standard semiconductor technology, good mechanical flexibility, high uniformity, and low operational voltage of 0.005 V. This work provides an effective method to enable oxide FET‐based biosensors for the fusion of multiplexed physicochemical information and wearable health monitoring applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Materials and Engineering, Zhejiang University, Hangzhou, 310027, China.
- Key Laboratory of 3D Micro/Nano Fabrication and Characterization of Zhejiang Province, School of Engineering, Westlake University, Hangzhou, 310024, China.
- Westlake Institute for Optoelectronics, Hangzhou, 311421, China.
- College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou, 310027, China.
- Enovated3D (Hangzhou) Technology Development Co., LTD., Hangzhou, 310051, China.
- College of Environmental & Resource Sciences, Zhejiang University, Hangzhou, 310058, China.
ORCID-Profile: Bowen Zhu
Förderung
- National Natural Science Foundation of China
- Westlake Institute for Optoelectronic
Zitieren
APA
Ren, H., Zhang, S., Li, D., Tang, Y., Chen, Y., Wang, Y., Liu, G., Li, F., Liu, L., Huang, Q., Xing, L., Chen, X., Wang, J., & Zhu, B. (2024). Wearable and Multiplexed Biosensors based on Oxide Field‐Effect Transistors. Small Methods. https://doi.org/10.1002/smtd.202400781
Vancouver
Ren H, Zhang S, Li D, Tang Y, Chen Y, Wang Y, et al. Wearable and Multiplexed Biosensors based on Oxide Field‐Effect Transistors. Small Methods. 2024. doi:10.1002/smtd.202400781
BibTeX
@article{Ren2024,
author = {Ren, Huihui and Zhang, Siyu and Li, Dingwei and Tang, Yingjie and Chen, Yitong and Wang, Yan and Liu, Guolei and Li, Fanfan and Liu, Lihua and Huang, Qi and Xing, Lixiang and Chen, Xiaopeng and Wang, Juan and Zhu, Bowen},
title = {Wearable and Multiplexed Biosensors based on Oxide Field‐Effect Transistors},
journal = {Small Methods},
year = {2024},
doi = {10.1002/smtd.202400781}
}
EUVIMED