EUVIMEDEUVIMED entdecken
Crossref

Stretchable Wrinkled‐Gold Antenna for High‐Sensitivity Intraocular Pressure Monitoring Smart Contact Lens

Te Xiao, Saman Azhari, Hanzhe Zhang, Yang Cui, Bingfu Liu, Taiki Takamatsu, Dingliang Xu, Atsushige Ashimori, Kazuhiro Kimura, Takeo Miyake

Advanced Materials Technologies · 13.11.2026

DOI: 10.1002/admt.71460 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Materials Technologies, online erschienen am 13.11.2026. Verfasst von Te Xiao und 9 weiteren Autor:innen. Die Arbeit nennt 46 Literaturangaben. Gefördert von: Japan Agency for Medical Research and Development.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Glaucoma is the main cause of irreversible blindness worldwide, and it is closely related to intraocular pressure (IOP). However, single or short‐term IOP measurements cannot fully reflect the biomechanical environment in the eye and the risk of disease progression. Therefore, continuous daily IOP monitoring is very important for the early diagnosis and long‐term treatment of glaucoma. To solve this problem, this study proposes a smart contact lens sensor that combines the Inductor‐Capacitor resonant circuit principle with a sandwich‐structured, wrinkled gold antenna for wireless IOP monitoring. By structurally modifying conventional materials, the device can flexibly adapt to eyeball deformation while maintaining excellent electrical stability. The results show that the sensor's sensitivity is 0.54 MHz·mmHg −1 in the balloon model and 0.25 MHz·mmHg −1 in the ex vivo porcine eye, with a good linear relationship between IOP changes and resonance frequency shifts. IOP was also successfully monitored in vivo using a live rabbit. Cytotoxicity experiments show that cell survival exceeds 99%, indicating good biocompatibility of the device at the cellular level. This study provides a new technical direction for integrating contact lens sensors with wearable devices, such as smart glasses, to enable continuous, non‐invasive IOP monitoring in daily life.

Förderung

  • Japan Agency for Medical Research and Development

Zitieren

APA

Xiao, T., Azhari, S., Zhang, H., Cui, Y., Liu, B., Takamatsu, T., Xu, D., Ashimori, A., Kimura, K., & Miyake, T. (2026). Stretchable Wrinkled‐Gold Antenna for High‐Sensitivity Intraocular Pressure Monitoring Smart Contact Lens. Advanced Materials Technologies. https://doi.org/10.1002/admt.71460

Vancouver

Xiao T, Azhari S, Zhang H, Cui Y, Liu B, Takamatsu T, et al. Stretchable Wrinkled‐Gold Antenna for High‐Sensitivity Intraocular Pressure Monitoring Smart Contact Lens. Advanced Materials Technologies. 2026. doi:10.1002/admt.71460

BibTeX
@article{Xiao2026,
  author = {Xiao, Te and Azhari, Saman and Zhang, Hanzhe and Cui, Yang and Liu, Bingfu and Takamatsu, Taiki and Xu, Dingliang and Ashimori, Atsushige and Kimura, Kazuhiro and Miyake, Takeo},
  title = {Stretchable Wrinkled‐Gold Antenna for High‐Sensitivity Intraocular Pressure Monitoring Smart Contact Lens},
  journal = {Advanced Materials Technologies},
  year = {2026},
  doi = {10.1002/admt.71460}
}
Kostenlos starten →