EUVIMEDEUVIMED entdecken
Crossref

Smart Contact Lens with High Sensitivity and Biocompatibility for Continuous Non-Invasive Intraocular Pressure Monitoring

Yunhao Tai, Qilong Cheng, Yuteng Liu, Xingqi Lu, Ting Xu, Xiaojian Li, Ping Liu iD, Tingting Luo iD, Guangli Liu, Yijing Gan, Runhuai Yang iD

ACS Sensors · 2025

DOI: 10.1021/acssensors.5c00883 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2025. Verfasst von Yunhao Tai und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, 3D-Printing and Tissue Engineering Center, Anhui Medical University, Hefei 230032, China. Hauptthemen laut MEDLINE: Intraocular Pressure, Contact Lenses, Biocompatible Materials, Tonometry, Ocular. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: Major Science and Technology Projects in Anhui Province, National Natural Science Foundation of China, ?Four New? Research and Reform Practice Project (Emerging Engineering Education) of Anhui Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Intelligent intraocular pressure (IOP) sensors capable of continuous monitoring play a crucial role in the treatment of glaucoma. However, early diagnosis and treatment continue to face significant challenges due to the unique physiological environment of the eye. The primary scientific challenge lies in developing a method for continuous, high-sensitivity IOP monitoring that does not damage corneal tissue. To address this issue, a novel smart contact lens was developed, integrating hydrogel-based micronano architectures with diffraction-grating-embedded films. This device leverages 3D printing technology to achieve conformal adhesion to the ocular surface, enabling real-time IOP monitoring through optical-to-digital signal transduction. Additionally, ex vivo porcine eyeballs were used for in vitro testing and evaluation to quantitatively demonstrate the performance of the smart sensor. The results indicate that the smart contact lens developed in this study exhibits excellent biocompatibility and a high sensitivity of 2.5% mmHg-1 within the range of 0-50 mmHg, enabling precise IOP monitoring. These lenses hold significant potential for clinical IOP monitoring and demonstrate substantial promise for the next generation of ocular disease prevention.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intraocular PressureContact LensesBiocompatible MaterialsTonometry, OcularAnimalsSwineHydrogelsPrinting, Three-DimensionalHumansMonitoring, Physiologic

Stichwörter der Autor:innen

3D printingbiocompatibilityintraocular pressure monitoringsmart contact lensstress collection

Substanzen

HydrogelsBiocompatible Materials

Autor:innen und Institutionen

  • School of Biomedical Engineering, 3D-Printing and Tissue Engineering Center, Anhui Medical University, Hefei 230032, China.
  • Key Laboratory of Process Optimization and Intelligent Decision-making, School of Management, Hefei University of Technology, Hefei 230009, China.
  • Sensitive Electronics and Sensors Research Group, School of Electronic Science and Applied Physics, Hefei University of Technology, Hefei 230009, China.
  • Department of Ophthalmology, The First Affiliated Hospital of University of Science and Technology of China, Hefei 230036, China.

ORCID-Profile: Ping Liu, Tingting Luo, Runhuai Yang

Förderung

  • Major Science and Technology Projects in Anhui Province
  • National Natural Science Foundation of China
  • ?Four New? Research and Reform Practice Project (Emerging Engineering Education) of Anhui Province
  • Outstanding Youth Research Project in Universities of Anhui Province
  • Scientific research improvement Foundation of Anhui Medical University
  • Technical development project of Anhui Medical University

Zitieren

APA

Tai, Y., Cheng, Q., Liu, Y., Lu, X., Xu, T., Li, X., Liu, P., Luo, T., Liu, G., Gan, Y., & Yang, R. (2025). Smart Contact Lens with High Sensitivity and Biocompatibility for Continuous Non-Invasive Intraocular Pressure Monitoring. ACS Sensors. https://doi.org/10.1021/acssensors.5c00883

Vancouver

Tai Y, Cheng Q, Liu Y, Lu X, Xu T, Li X, et al. Smart Contact Lens with High Sensitivity and Biocompatibility for Continuous Non-Invasive Intraocular Pressure Monitoring. ACS Sensors. 2025. doi:10.1021/acssensors.5c00883

BibTeX
@article{Tai2025,
  author = {Tai, Yunhao and Cheng, Qilong and Liu, Yuteng and Lu, Xingqi and Xu, Ting and Li, Xiaojian and Liu, Ping and Luo, Tingting and Liu, Guangli and Gan, Yijing and Yang, Runhuai},
  title = {Smart Contact Lens with High Sensitivity and Biocompatibility for Continuous Non-Invasive Intraocular Pressure Monitoring},
  journal = {ACS Sensors},
  year = {2025},
  doi = {10.1021/acssensors.5c00883}
}
Kostenlos starten →