Intraocular Pressure Monitoring Smart Contact Lens with High Environmental Stability
Advanced Functional Materials · 2024-08 · 34 (34)
DOI: 10.1002/adfm.202400722 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Functional Materials, online erschienen am 09.04.2024. Verfasst von Huan Yang und 8 weiteren Autor:innen. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Smart contact lenses (SCLs), integrating various functional components, serve as a platform for wirelessly intraocular pressure (IOP) monitoring. Accurate and dynamic measurements offer crucial clinical references for patients with ocular hypertension. Nevertheless, the complex ocular environment poses great challenges, particularly for inductor–capacitor–resistor (LCR) type IOP sensors, which suffer signal instability due to variations of ocular dielectric properties. Here, an innovative IOP monitoring sensor with robust environmental stability, achieved by integrating the ground shield, is proposed. Employing a capacitive pressure sensor with porous polydimethylsiloxane (PDMS) structure encased in a hydrogel, the study successfully demonstrates high‐sensitivity monitoring of IOP changes using in vitro porcine eyes. This optimized design empowers the wireless IOP sensor with a sensitivity of 1.15 ‰/mmHg. It exhibits exceptional frequency stability after undergoing 100 wear cycles on ten distinct porcine eyes and remains reliable across a wide range of metabolite concentrations typical of normal eyes. Notably, any observed frequency shift translates into IOP changes within a 3 mmHg range, showcasing its suitability for repeated use and daily IOP monitoring.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Yang, H., Zhu, H., Liu, H., Mao, Z., Luo, J., Zhu, S., Hu, Z., Yuan, S., & Xu, F. (2024). Intraocular Pressure Monitoring Smart Contact Lens with High Environmental Stability. Advanced Functional Materials, 34(34). https://doi.org/10.1002/adfm.202400722
Vancouver
Yang H, Zhu H, Liu H, Mao Z, Luo J, Zhu S, et al. Intraocular Pressure Monitoring Smart Contact Lens with High Environmental Stability. Advanced Functional Materials. 2024;34(34). doi:10.1002/adfm.202400722
BibTeX
@article{Yang2024,
author = {Yang, Huan and Zhu, Hengtian and Liu, Hanwen and Mao, Zhengyi and Luo, Junxian and Zhu, Shugeng and Hu, Zizhong and Yuan, Songtao and Xu, Fei},
title = {Intraocular Pressure Monitoring Smart Contact Lens with High Environmental Stability},
journal = {Advanced Functional Materials},
year = {2024},
volume = {34},
number = {34},
doi = {10.1002/adfm.202400722}
}
EUVIMED