Molecular‐Device Co‐Engineering of Ultra‐Low Dark Current SWIR Organic Photodetectors for High‐Quality Blood‐Pressure Monitoring and Optical Communication
Advanced Materials · 2025-11 · 37 (44)
DOI: 10.1002/adma.202509923 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Materials, online erschienen am 22.08.2025. Verfasst von Junhao Zeng und 10 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Polymer Optoelectronic Materials and Devices, State Key Laboratory of Luminescent Materials and Devices, South China University of Techn…. Die Arbeit wurde bisher 41-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: Guangdong Basic and Applied Basic Research Foundation, 111 Project, High Performance Computing Platform of South China University of Technology.
Abstract (Originalsprache)
The limited noise‐responsivity balance in Short‐wave infrared (SWIR) organic photodetectors (OPDs) restricts their biomedical and optoelectronic applications. In this study, this challenge is addressed through molecular‐device co‐engineering by designing two fluorinated narrow‐bandgap non‐fullerene acceptors (BTT‐DTPn and BTT‐DTPn‐2F) coupled with solvent vapor annealing (SVA), achieving low noise and high detectivity in SWIR OPDs. The optimized devices based on BTT‐DTPn‐2F, which features enhance π–π stacking due to terminal fluorination, extend its absorption capability to 1300 nm. Under −0.1 V bias, the SVA‐processed BTT‐DTPn‐2F devices demonstrate an ultra‐low dark current ( J d ) of 4.93 × 10 −8 A cm −2 and exhibit a suppressed trap density of states (tDOS) reduced by an order of magnitude, achieving a shot‐noise limited detectivity () of 7.19 × 10 11 Jones at 1200 nm. The synergy of molecular design and post‐processing enables an ultra‐fast response time (1.44/1.20 µs rise/fall) and a record‐high −3 dB cutoff frequency ( f −3 dB ) of 648 kHz, demonstrating remarkable performance for SWIR OPDs. These advancements facilitate two groundbreaking applications: deep‐tissue photoplethysmography (PPG) for cuff‐less blood pressure monitoring and high‐speed, real‐time SWIR optical communication. This methodology presents a general strategy to harmonize molecular design with device fabrication in SWIR OPDs.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Polymer Optoelectronic Materials and Devices, State Key Laboratory of Luminescent Materials and Devices, South China University of Technology, Guangzhou, 510640, P. R. China.
- School of Optoelectronic Engineering, Guangdong Polytechnic Normal University, Guangzhou, 510665, P. R. China.
- Dongguan Key Laboratory of Interdisciplinary Science for Advanced Materials and Large-Scale Scientific Facilities, School of Physical Sciences, Great Bay University, Dongguan, Guangdong, 523000, P. R. China.
ORCID-Profile: Junhao Zeng, Ruihao Xie, Zhicai He
Förderung
- Guangdong Basic and Applied Basic Research Foundation
- 111 Project
- High Performance Computing Platform of South China University of Technology
- Basic and Applied Basic Research Foundation of Guangdong Province
- Higher Education Discipline Innovation Project
Zitieren
APA
Zeng, J., Ren, Z., Lin, D., Gong, W., Song, G., Wu, L., Liu, S., Wu, J., Jia, T., Xie, R., & He, Z. (2025). Molecular‐Device Co‐Engineering of Ultra‐Low Dark Current SWIR Organic Photodetectors for High‐Quality Blood‐Pressure Monitoring and Optical Communication. Advanced Materials, 37(44). https://doi.org/10.1002/adma.202509923
Vancouver
Zeng J, Ren Z, Lin D, Gong W, Song G, Wu L, et al. Molecular‐Device Co‐Engineering of Ultra‐Low Dark Current SWIR Organic Photodetectors for High‐Quality Blood‐Pressure Monitoring and Optical Communication. Advanced Materials. 2025;37(44). doi:10.1002/adma.202509923
BibTeX
@article{Zeng2025,
author = {Zeng, Junhao and Ren, Zhihua and Lin, Dingming and Gong, Weiyang and Song, Gang and Wu, Lunbi and Liu, Sha and Wu, Jifa and Jia, Tao and Xie, Ruihao and He, Zhicai},
title = {Molecular‐Device Co‐Engineering of Ultra‐Low Dark Current SWIR Organic Photodetectors for High‐Quality Blood‐Pressure Monitoring and Optical Communication},
journal = {Advanced Materials},
year = {2025},
volume = {37},
number = {44},
doi = {10.1002/adma.202509923}
}
EUVIMED