EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Portable Breathing Monitoring With Phase‐Resolved Airflow Dynamics Enabled by a Dual‐Response Flexible PZT Sensor

Minyu Li, Jun Aoyama, Yuchao Wu, Tomomi Uchiyama, Kosho Yoshikawa iD, Toshiki Mano iD, Yuxi Song iD, Hedong Zhang iD

Advanced Healthcare Materials · 2026-07 · 15 (25)

DOI: 10.1002/adhm.71282 ↗

At a glance

Journal article in Advanced Healthcare Materials, published online on 2026-05-28. Written by Minyu Li and 7 co-authors. Institution: Department of Complex Systems Science, Graduate School of Informatics, Nagoya University, Nagoya, Japan. Major MEDLINE topics: Lead, Titanium, Zirconium, Respiration. 42 references. The full text is freely available (open access, CC BY 4.0). Funded by: JSPS KAKENHI, Japan Science and Technology Agency.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Respiratory monitoring in daily‐life settings is important for health assessment, yet extracting physiologically interpretable information from breathing signals under natural conditions remains challenging, as breathing is inherently dynamic and strongly modulated by behavior. Here, a portable breathing monitoring device based on a flexible lead zirconate titanate sensor is developed to address this challenge. By exploiting polarity‐opposed piezoelectric and pyroelectric responses through sensor orientation, the recorded breathing waveform exhibits a characteristic dual‐component structure, consisting of a narrow transient spike followed by a broad quasi‐steady peak within each breathing phase. This intrinsic waveform structure enables phase‐resolved quantification of how breathing effort is distributed between transient and quasi‐steady components during inhalation and exhalation. Pilot measurements and exploratory analyses in healthy subjects and patients with chronic obstructive pulmonary disease or asthma suggest a phase‐specific redistribution of breathing dynamics in patients, mainly characterized by a coupled decrease in quasi‐steady inhalation contribution and an increase in transient exhalation contribution. By transforming complex breathing dynamics into stable and physiologically meaningful signal components, this dual‐response sensing approach enables more robust access to function‐related changes during natural breathing in daily life.

Subjects

MeSH terms (MEDLINE)

LeadTitaniumZirconiumRespirationHumansMonitoring, PhysiologicPulmonary Disease, Chronic ObstructiveAsthma

Author keywords

Respiratory monitoringflexible PZT sensorintra‐cycle analysisphase‐resolved breathing dynamicspiezoelectric–pyroelectric couplingportable healthcare devices

Substances

LeadTitaniumZirconiumlead titanate zirconate

Authors and institutions

  • Department of Complex Systems Science, Graduate School of Informatics, Nagoya University, Nagoya, Japan.
  • Institute of Materials and Systems for Sustainability, Nagoya University, Nagoya, Japan.
  • Department of Respiratory Medicine, Daido Hospital, Kojunkai Social Medical Corporation, Nagoya, Japan.
  • Chuo Graduate School of Strategic Management, Chuo University, Tokyo, Japan.

ORCID profiles: Kosho Yoshikawa, Toshiki Mano, Yuxi Song, Hedong Zhang

Funding

  • JSPS KAKENHI
  • Japan Science and Technology Agency

Cite

APA

Li, M., Aoyama, J., Wu, Y., Uchiyama, T., Yoshikawa, K., Mano, T., Song, Y., & Zhang, H. (2026). Portable Breathing Monitoring With Phase‐Resolved Airflow Dynamics Enabled by a Dual‐Response Flexible PZT Sensor. Advanced Healthcare Materials, 15(25). https://doi.org/10.1002/adhm.71282

Vancouver

Li M, Aoyama J, Wu Y, Uchiyama T, Yoshikawa K, Mano T, et al. Portable Breathing Monitoring With Phase‐Resolved Airflow Dynamics Enabled by a Dual‐Response Flexible PZT Sensor. Advanced Healthcare Materials. 2026;15(25). doi:10.1002/adhm.71282

BibTeX
@article{Li2026,
  author = {Li, Minyu and Aoyama, Jun and Wu, Yuchao and Uchiyama, Tomomi and Yoshikawa, Kosho and Mano, Toshiki and Song, Yuxi and Zhang, Hedong},
  title = {Portable Breathing Monitoring With Phase‐Resolved Airflow Dynamics Enabled by a Dual‐Response Flexible PZT Sensor},
  journal = {Advanced Healthcare Materials},
  year = {2026},
  volume = {15},
  number = {25},
  doi = {10.1002/adhm.71282}
}
Start for free →