Feasibility Study for a High-Frequency Flexible Ultrasonic Cuff for High-Precision Vagus Nerve Ultrasound Neuromodulation
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2024
DOI: 10.1109/tuffc.2024.3381923 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2024. Verfasst von Cornelis van Damme und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Feasibility Studies, Transducers, Equipment Design, Vagus Nerve Stimulation. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Gefördert von: Electronic Components and Systems for European Leadership (ECSEL) Joint Undertaking project Moore4Medical, CHIPS Joint Undertaking NerveRepack.
Abstract (Originalsprache)
In the emerging research field of bioelectronic medicine, it has been indicated that neuromodulation of the vagus nerve (VN) has the potential to treat various conditions such as epilepsy, depression, and autoimmune diseases. In order to reduce side effects, as well as to increase the effectiveness of the delivered therapy, sub-fascicle stimulation specificity is required. In the electrical domain, increasing spatial selectivity can only be achieved using invasive and potentially damaging approaches like compressive forces or nerve penetration. To avoid these invasive methods while obtaining a high spatial selectivity, a 2-mm diameter extraneural cuff-shaped proof-of-concept design with integrated lead zirconate titanate (PZT) based ultrasound (US) transducers is proposed in this article. For the development of the proposed concept, wafer-level microfabrication techniques are employed. Moreover, acoustic measurements are performed on the device, in order to characterize the ultrasonic beam profiles of the integrated PZT-based US transducers. A focal spot size of around [Formula: see text] is measured for the proposed cuff. Moreover, the curvature of the device leads to constructive interference of the US waves originating from multiple PZT-based US transducers, which in turn leads to an increase of 45% in focal pressure compared to the focal pressure of a single PZT-based US transducer. Integrating PZT-based US transducers in an extraneural cuff-shaped design has the potential to achieve high-precision US neuromodulation of the VN without requiring intraneural implantation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Förderung
- Electronic Components and Systems for European Leadership (ECSEL) Joint Undertaking project Moore4Medical
- CHIPS Joint Undertaking NerveRepack
Zitieren
APA
van Damme, C., Wardhana, G. K., Velea, A. I., Giagka, V., & Costa, T. L. (2024). Feasibility Study for a High-Frequency Flexible Ultrasonic Cuff for High-Precision Vagus Nerve Ultrasound Neuromodulation. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2024.3381923
Vancouver
van Damme C, Wardhana GK, Velea AI, Giagka V, Costa TL. Feasibility Study for a High-Frequency Flexible Ultrasonic Cuff for High-Precision Vagus Nerve Ultrasound Neuromodulation. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2024. doi:10.1109/tuffc.2024.3381923
BibTeX
@article{vanDamme2024,
author = {van Damme, Cornelis and Wardhana, Gandhika K and Velea, Andrada Iulia and Giagka, Vasiliki and Costa, Tiago L},
title = {Feasibility Study for a High-Frequency Flexible Ultrasonic Cuff for High-Precision Vagus Nerve Ultrasound Neuromodulation},
journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
year = {2024},
doi = {10.1109/tuffc.2024.3381923}
}
EUVIMED