Recording Quality Is Systematically Related to Electrode Impedance
Advanced Healthcare Materials · 2024-09 · 13 (24)
DOI: 10.1002/adhm.202303401 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, online erschienen am 23.02.2024. Verfasst von Christopher M Lewis und 5 weiteren Autor:innen. Beteiligte Einrichtung: Brain Research Institute, University of Zurich, Zurich, 8057, Switzerland. Hauptthemen laut MEDLINE: Electric Impedance, Microelectrodes. Die Arbeit wurde bisher 68-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: University of Zurich, German Research Foundation, Federal Ministry of Economics, Science and Arts of Baden Württemberg.
Abstract (Originalsprache)
Extracellular recordings with planar microelectrodes are the gold standard technique for recording the fast action potentials of neurons in the intact brain. The introduction of microfabrication techniques has revolutionized the in vivo recording of neuronal activity and introduced high‐density, multi‐electrode arrays that increase the spatial resolution of recordings and the number of neurons that can be simultaneously recorded. Despite these innovations, there is still debate about the ideal electrical transfer characteristics of extracellular electrodes. This uncertainty is partly due to the lack of systematic studies comparing electrodes with different characteristics, particularly for chronically implanted arrays over extended time periods. Here a high‐density, flexible, and thin‐film array is fabricated and tested, containing four distinct electrode types differing in surface material and surface topology and, thus, impedance. It is found that recording quality is strongly related to electrode impedance with signal amplitude and unit yield negatively correlated to impedance. Electrode impedances are stable for the duration of the experiment (up to 12 weeks) and recording quality does not deteriorate. The findings support the expectation from the theory that recording quality will increase as impedance decreases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Brain Research Institute, University of Zurich, Zurich, 8057, Switzerland.
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany.
- BrainLinks-BrainTools Center, University of Freiburg, 79110, Freiburg, Germany.
- Ernst Strüngmann Institute (ESI) for Neuroscience in Cooperation with Max Planck Society, Deutschordenstraße 46, 60528, Frankfurt, Germany.
- Donders Institute for Brain, Cognition and Behaviour, Radboud University, Kapittelweg 29, 6525 EN, Nijmegen, Netherland.
- Department of Microtechnology and Nanoscience, Chalmers University of Technology, Kemivägen 9, Gothenburg, 41258, Sweden.
ORCID-Profile: Christopher M Lewis, Christian Boehler, Pascal Fries, Thomas Stieglitz, Maria Asplund
Förderung
- University of Zurich
- German Research Foundation
- Federal Ministry of Economics, Science and Arts of Baden Württemberg
- European Union's Horizon 2020 Research and Innovation Program
- Universität Zürich
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Lewis, C. M., Boehler, C., Liljemalm, R., Fries, P., Stieglitz, T., & Asplund, M. (2024). Recording Quality Is Systematically Related to Electrode Impedance. Advanced Healthcare Materials, 13(24). https://doi.org/10.1002/adhm.202303401
Vancouver
Lewis CM, Boehler C, Liljemalm R, Fries P, Stieglitz T, Asplund M. Recording Quality Is Systematically Related to Electrode Impedance. Advanced Healthcare Materials. 2024;13(24). doi:10.1002/adhm.202303401
BibTeX
@article{Lewis2024,
author = {Lewis, Christopher M and Boehler, Christian and Liljemalm, Rickard and Fries, Pascal and Stieglitz, Thomas and Asplund, Maria},
title = {Recording Quality Is Systematically Related to Electrode Impedance},
journal = {Advanced Healthcare Materials},
year = {2024},
volume = {13},
number = {24},
doi = {10.1002/adhm.202303401}
}