Understanding the Effects of Conductive Polymer Electrode Coating on Recorded Neural Signals
Advanced Healthcare Materials · 2026
DOI: 10.1002/adhm.202503893 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2026. Verfasst von Karthik Sridhar und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical and Electronic Engineering, University College Dublin, Dublin, Ireland. Hauptthemen laut MEDLINE: Polymers, Bridged Bicyclo Compounds, Heterocyclic, Coated Materials, Biocompatible, Neurons. Die Arbeit nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Ireland and the European Regional Development Fund, European Research Council.
Abstract (Originalsprache)
Conductive polymer coatings have been extensively explored as a means of improving the quality of neural signals recorded with chronically implanted electrodes. They offer enhanced biocompatibility along with reduced electrode impedance and are reported to improve signal‐to‐noise ratio and signal amplitude. The mechanisms by which poly(3,4ethylenedioxythiophene) (PEDOT) and its derivatives enhance the quality of neural signals recorded in vivo, however, remain unclear. Here, a computational model of PEDOT:PTS (polythiophenesulfonyl chloride) coated neural recording electrodes is used to understand how the different properties of conductive electrode coatings influence local field potentials recorded in vivo. Impedance, histology and electrophysiology data were obtained from coated and uncoated microelectrodes chronically implanted in the rat basal ganglia and incorporated in the model. Together the simulation and experimental results indicate that improvements in signal quality with PEDOT:PTS coated electrodes are driven by greater neural proximity to the electrode, facilitated by reduced peri‐electrode gliosis. Reductions in thermal noise with decreasing electrode impedance further contributed to a higher signal‐to‐noise ratio for PEDOT:PTS coated electrodes. Finally, the results demonstrate that, provided amplifier input impedance requirements are satisfied, the enhanced recording capability of polymer coated electrodes compared to uncoated electrodes is due primarily to improved biocompatibility rather than reduced electrode impedance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Electrical and Electronic Engineering, University College Dublin, Dublin, Ireland.
- Research Ireland CÚRAM Research Centre For Medical Devices, University of Galway, Ireland.
- School of Veterinary Medicine, University College Dublin, Dublin, Ireland.
- Paris Brain Institute (ICM), Inserm U1127, CNRS UMR 7225, Sorbonne University, Hôpital de la Pitié-Salpêtrière, Paris, 75013, France.
ORCID-Profile: Madeleine M Lowery
Förderung
- Research Ireland and the European Regional Development Fund
- European Research Council
Zitieren
APA
Sridhar, K., Evers, J., Trotier, A., Biggs, M., & Lowery, M. M. (2026). Understanding the Effects of Conductive Polymer Electrode Coating on Recorded Neural Signals. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202503893
Vancouver
Sridhar K, Evers J, Trotier A, Biggs M, Lowery MM. Understanding the Effects of Conductive Polymer Electrode Coating on Recorded Neural Signals. Advanced Healthcare Materials. 2026. doi:10.1002/adhm.202503893
BibTeX
@article{Sridhar2026,
author = {Sridhar, Karthik and Evers, Judith and Trotier, Alexandre and Biggs, Manus and Lowery, Madeleine M},
title = {Understanding the Effects of Conductive Polymer Electrode Coating on Recorded Neural Signals},
journal = {Advanced Healthcare Materials},
year = {2026},
doi = {10.1002/adhm.202503893}
}
EUVIMED