Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 19.11.2026. Verfasst von Jared M. Baggett und 7 weiteren Autor:innen. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institute of Biomedical Imaging and Bioengineering, National Cancer Institute.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To develop a slice‐specific dose library and supporting interpolation scheme for proper estimation of organ doses from CT scans based on the UF/MSK mesh‐type adult and pediatric phantom series.

Methods

Monte Carlo (MC) simulations were performed using the Particle and Heavy Ion Transport code System (PHITS) for selected adult female and pediatric male phantoms across a user defined CT source term. Dose profiles were calculated on a 1‐cm slice basis and categorized by tissue type (distributed vs. non‐distributed). Linear interpolation of slice doses within a height series was evaluated using multiple phantom subsets and compared against MC results.

Results

Slice‐by‐slice linear interpolation produced total organ dose estimates within 5% of MC values for most studied tissues, with all errors below 7%. Mean errors for abdomen, chest‐abdomen‐pelvis and cardiac scan ranges were also below 5%, and mean errors for individual slices were below 3%. The method performed well across various interpolation schemes, especially when phantoms were selected based on similar construction methods.

Conclusions

This approach enables accurate, scalable organ dose estimation with reduced computational demands. The resulting dose library and interpolation method will be integrated into the MIRDct platform, a dosimetry tool for calculating total organ dose values across a wide range of CT parameters. MIRDct is freely available to the medical imaging community at MIRDsoft.org.

Förderung

  • National Institute of Biomedical Imaging and Bioengineering
  • National Cancer Institute

Zitieren

APA

Baggett, J. M., Dinwiddie, L. E., Dawson, R. J., Ramos, J. C. O., Kayal, G., Carter, L. M., Kesner, A. L., & Bolch, W. E. (2026). Development of a slice‐specific ct dose library with interpolation methods for organ dosimetry in MIRDct. Journal of Applied Clinical Medical Physics, 27(12). https://doi.org/10.1002/acm2.70914

Vancouver

Baggett JM, Dinwiddie LE, Dawson RJ, Ramos JCO, Kayal G, Carter LM, et al. Development of a slice‐specific ct dose library with interpolation methods for organ dosimetry in MIRDct. Journal of Applied Clinical Medical Physics. 2026;27(12). doi:10.1002/acm2.70914

BibTeX
@article{Baggett2026,
  author = {Baggett, Jared M. and Dinwiddie, Laura E. and Dawson, Robert J. and Ramos, Juan C. Ocampo and Kayal, Gunjan and Carter, Lukas M. and Kesner, Adam L. and Bolch, Wesley E.},
  title = {Development of a slice‐specific ct dose library with interpolation methods for organ dosimetry in MIRDct},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  volume = {27},
  number = {12},
  doi = {10.1002/acm2.70914}
}
Kostenlos starten →