Fachartikel in der Zeitschrift Journal of Imaging Informatics in Medicine, online erschienen am 30.03.2026. Verfasst von Abdellah Khallouqi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Sciences and Engineering of Biomedicals, Biophysics and Health Laboratory, Higher Institute of Health Sciences, Hassan First University, Settat, Moro…. Die Arbeit nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study introduces an automated Python-based framework for the accurate calculation of water-equivalent diameter (Dw), effective diameter (Deff), and size-specific dose estimate (SSDE) using a hybrid segmentation strategy. The algorithm integrates DICOM metadata extraction, Hounsfield Unit (HU) conversion, and interactive anatomical segmentation, combining automated HU thresholding with user-guided refinement and morphological processing to ensure robust contour delineation. The framework was validated against commercial software (Indose_CT) and expert manual segmentation using 470 clinical CT scans (270 head and 200 chest). For head scans, strong agreement was observed for Dw (r = 0.960, bias = 0.016 cm) and SSDE (r = 0.960, bias = 0.78 mGy). Chest scans demonstrated excellent accuracy, with Dw (r = 0.987, bias = 0.16 cm) and SSDE (r = 0.999, bias = 0.008 mGy). Expert validation on 100 cases confirmed near-expert segmentation performance, achieving Dice similarity coefficients of 0.966 ± 0.018 (head) and 0.953 ± 0.024 (chest), Hausdorff distances of 2.6 ± 0.8 mm (head) and 3.1 ± 1.2 mm (chest), and average surface distances below 2 mm. Importantly, segmentation discrepancies resulted in clinically negligible dosimetric differences: mean SSDE deviations were 0.360 ± 0.252 mGy (0.94%) for head and 0.142 ± 0.097 mGy (1.26%) for chest, with 98% of cases showing less than 2% deviation from expert measurements. The proposed hybrid approach effectively addresses segmentation challenges in complex anatomical cases through real-time user adjustment while maintaining efficient batch-processing capabilities via an intuitive graphical interface.

Schlagwörter

Stichwörter der Autor:innen

Automated segmentationCT imagingEffective diameterRadiation dose optimizationSize-specific dose estimateWater-equivalent diameter

Autor:innen und Institutionen

  • Sciences and Engineering of Biomedicals, Biophysics and Health Laboratory, Higher Institute of Health Sciences, Hassan First University, Settat, Morocco. a.khallouqi@uhp.ac.ma.
  • Sciences and Engineering of Biomedicals, Biophysics and Health Laboratory, Higher Institute of Health Sciences, Hassan First University, Settat, Morocco.

Zitieren

APA

Khallouqi, A., Sekkat, H., Halimi, A., Rhazouani, O. E., & Drissi, A. (2026). From DICOM to Dose: An Automated Python Platform for Patient-Specific CT Dosimetry. Journal of Imaging Informatics in Medicine. https://doi.org/10.1007/s10278-026-01945-9

Vancouver

Khallouqi A, Sekkat H, Halimi A, Rhazouani OE, Drissi A. From DICOM to Dose: An Automated Python Platform for Patient-Specific CT Dosimetry. Journal of Imaging Informatics in Medicine. 2026. doi:10.1007/s10278-026-01945-9

BibTeX
@article{Khallouqi2026,
  author = {Khallouqi, Abdellah and Sekkat, Hamza and Halimi, Abdellah and Rhazouani, Omar El and Drissi, Anass},
  title = {From DICOM to Dose: An Automated Python Platform for Patient-Specific CT Dosimetry},
  journal = {Journal of Imaging Informatics in Medicine},
  year = {2026},
  doi = {10.1007/s10278-026-01945-9}
}
Kostenlos starten →