Automated offline adaptive radiotherapy through CBCT imaging: A multidimensional feasibility study of hypersight and iterative CBCT

Ben R Archibald-Heeren iD, Aidan Leong, Nigel Middlebrook, Peter Phung, Sarah Hauville, Yunfei Hu iD, Gayan Singappulige, Trent J Aland

Journal of Applied Clinical Medical Physics · 2026

DOI: 10.1002/acm2.70853 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Ben R Archibald-Heeren und 7 weiteren Autor:innen. Beteiligte Einrichtung: Icon Group, Clinical Care, Brisbane, Queensland, Australia. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Radiotherapy Planning, Computer-Assisted, Image Processing, Computer-Assisted, Radiotherapy, Image-Guided. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Siemens-Healthineers, Icon Cancer Centres.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Offline adaptive radiotherapy (OffART) offers potential dosimetric and clinical advantages by adjusting planned dosimetry in response to systematic patient changes throughout treatment, however implementation is associated with an increased labor burden. Technological innovations in automated contouring, image registration and on‐board imaging present the opportunity for an automated workflow that achieves the benefit of OffART with a reduced impact on staff workload.

Purpose

To assess if the image quality of a ring‐based cone beam computed tomography (CBCT) imaging system is sufficient to enable automated contouring, deformable image registration (DIR), and dose calculation, thereby facilitating the implementation of an automated offline adaptive workflow.

Methods

The treatment images for 40 clinical patients were retrospectively analyzed. The cohort spanned across multiple disease sites, including breast, thorax, abdomen, and male pelvis. Patients were selected from a clinical department utilizing the Varian Halcyon HyperSight (HypS) imaging system, and another department utilizing the Varian TrueBeam iterative cone‐beam CT (TB‐iCBCT) imaging system. Automated processes, without human intervention, were completed using the IGRT images and compared with planning simulation CT (pCT) images. Images were assessed for region of interest truncation, automated contouring agreement, DIR accuracy, and dose calculation accuracy using qualitative visual assessment, dice similarity coefficient (DSC) contour agreement and gamma analysis for dose calculation.

Results

HypS imaging demonstrated improvements in reduced structure truncation with a reduction of 8% of structures with major or complete truncation. 13/21 organs demonstrated improved automated contouring consistency with pCT in HypS relative to TB‐iCBCT. Overall DSC results for DIR propagated contours were higher in the HypS cohort, partially due to TB‐iCBCT image truncation and partially due to improved registrations on the HypS images. HypS imaging demonstrated stronger agreement with pCT reported tissue density in heterogeneous patient anatomy than TB‐iCBCT imaging. Dose calculation gamma results for HypS were on average higher than TB‐iCBCT when comparing to the pCT calculated dose, however patient specific anatomical changes resulted in variability in results. Both imaging systems scored high gamma passing rates for calculations on pelvis cases.

Conclusion

Improved image quality and field of view on the HypS imaging system results in improved system performance for several of the processes within the workflow for offline adaptation. Dose calculation and tissue density representation is of sufficient accuracy to warrant use of the imaging for offline adaptive radiotherapy. Automated contouring and contour propagation accuracy improved with HypS in some scenarios but remains the major barrier to a truly automated offline adaptive workflow not requiring human intervention.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyRadiotherapy Planning, Computer-AssistedImage Processing, Computer-AssistedRadiotherapy, Image-GuidedNeoplasmsHumansFeasibility StudiesRadiotherapy DosageMaleRetrospective StudiesRadiotherapy, Intensity-ModulatedFemaleOrgans at RiskAutomation

Stichwörter der Autor:innen

Adaptive RadiotherapyAutomated ContouringCBCTDeformable RegistrationHyperSight

Autor:innen und Institutionen

  • Icon Group, Clinical Care, Brisbane, Queensland, Australia.
  • Icon Cancer Centre Bowen, Wellington, New Zealand.
  • Icon Cancer Centre Holmesglen, Moorabbin, Victoria, Australia.
  • Icon Cancer Centre Gosford, Gosford, New South Wales, Australia.

ORCID-Profile: Ben R Archibald-Heeren, Yunfei Hu

Förderung

  • Siemens-Healthineers
  • Icon Cancer Centres

Zitieren

APA

Archibald-Heeren, B. R., Leong, A., Middlebrook, N., Phung, P., Hauville, S., Hu, Y., Singappulige, G., & Aland, T. J. (2026). Automated offline adaptive radiotherapy through CBCT imaging: A multidimensional feasibility study of hypersight and iterative CBCT. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70853

Vancouver

Archibald-Heeren BR, Leong A, Middlebrook N, Phung P, Hauville S, Hu Y, et al. Automated offline adaptive radiotherapy through CBCT imaging: A multidimensional feasibility study of hypersight and iterative CBCT. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70853

BibTeX
@article{ArchibaldHeeren2026,
  author = {Archibald-Heeren, Ben R and Leong, Aidan and Middlebrook, Nigel and Phung, Peter and Hauville, Sarah and Hu, Yunfei and Singappulige, Gayan and Aland, Trent J},
  title = {Automated offline adaptive radiotherapy through CBCT imaging: A multidimensional feasibility study of hypersight and iterative CBCT},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  doi = {10.1002/acm2.70853}
}
Kostenlos starten →