Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Hongwei Zeng und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiotherapy, Shuguang Hospital Affiliated to Shanghai University of Chinese Traditional Medicine, Shanghai, China. Hauptthemen laut MEDLINE: Deep Learning, Lung Neoplasms, Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Lung cancer poses a significant global health challenge. Adaptive radiotherapy (ART) addresses uncertainties due to lung tumor dynamics. We aimed to investigate a comprehensively and systematically validated offline ART regimen with high clinical feasibility for lung cancer.
Methods
This study enrolled 102 lung cancer patients, who underwent kV iterative cone‐beam computed tomography (iCBCT). Data collection included iCBCT and planning CT (pCT) scans. Among these, data from 70 patients were employed for training the UNet++ based deep learning model, while 15 patients were allocated for testing the model. The model transformed iCBCT into adaptive CT (aCT). Clinical radiotherapy feasibility was verified in 17 patients. The dosimetric evaluation encompassed GTV, organs at risk (OARs), and monitor units (MU), while delivery accuracy was validated using ArcCHECK and thermoluminescent dosimeter (TLD) detectors.
Results
The UNet++ based deep learning model substantially improved image quality, reducing mean absolute error (MAE) by 70.05%, increasing peak signal‐to‐noise ratio (PSNR) by 17.97%, structural similarity (SSIM) by 7.41%, and the Hounsfield Units (HU) of aCT approaching a closer proximity to pCT compared to kV iCBCT. There were no significant differences observed in the dosimetric parameters of GTV and OARs between the aCT and pCT plans, confirming the accuracy of the dose maps in ART plans. Similarly, MU manifested no notable disparities, underscoring the consistency in treatment efficiency. Gamma passing rates for intensity‐modulated radiation therapy (IMRT) and volumetric‐modulated arc therapy (VMAT) plans derived from aCT and pCT exceeded 98%, while the deviations in TLD measurements (within 2% to 7%) also exhibited no significant differences, thus corroborating the precision of dose delivery.
Conclusion
An offline ART regimen utilizing kV iCBCT and UNet++ based deep learning model is clinically feasible for lung cancer treatment. This approach provides enhanced image quality, comparable treatment plans to pCT, and precise dose delivery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiotherapy, Shuguang Hospital Affiliated to Shanghai University of Chinese Traditional Medicine, Shanghai, China.
- MedMind Technology Co Ltd, Beijing, China.
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
Zitieren
APA
Zeng, H., Chen, Q., E, X., Feng, Y., Lv, M., Zeng, S., Shen, W., Guan, W., Zhang, Y., Zhao, R., Wang, S., & Yu, J. (2025). Assessment of clinical feasibility:offline adaptive radiotherapy for lung cancer utilizing kV iCBCT and UNet++ based deep learning model. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14582
Vancouver
Zeng H, Chen Q, E X, Feng Y, Lv M, Zeng S, et al. Assessment of clinical feasibility:offline adaptive radiotherapy for lung cancer utilizing kV iCBCT and UNet++ based deep learning model. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.14582
BibTeX
@article{Zeng2025,
author = {Zeng, Hongwei and Chen, Qi and E, Xiangyu and Feng, Yue and Lv, Minghe and Zeng, Su and Shen, Wenhao and Guan, Wenhui and Zhang, Yang and Zhao, Ruping and Wang, Shaobin and Yu, Jingping},
title = {Assessment of clinical feasibility:offline adaptive radiotherapy for lung cancer utilizing kV iCBCT and UNet++ based deep learning model},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.14582}
}
EUVIMED