EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Feasibility of CycleGAN enhanced low dose CBCT imaging for prostate radiotherapy dose calculation

Y Chan iD, M Li, K Parodi, C Belka, G Landry iD, C Kurz

Physics in Medicine & Biology · 2023

DOI: 10.1088/1361-6560/acccce ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2023. Verfasst von Y Chan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University Hospital, LMU Munich, D-81377 Munich, Germany. Hauptthemen laut MEDLINE: Spiral Cone-Beam Computed Tomography, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Training Group GRK 2274, Deutsche Forschungsgemeinschaft.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Daily cone beam computed tomography (CBCT) imaging during the course of fractionated radiotherapy treatment can enable online adaptive radiotherapy but also expose patients to a non-negligible amount of radiation dose. This work investigates the feasibility of low dose CBCT imaging capable of enabling accurate prostate radiotherapy dose calculation with only 25% projections by overcoming under-sampling artifacts and correcting CT numbers by employing cycle-consistent generative adversarial networks (cycleGAN). Uncorrected CBCTs of 41 prostate cancer patients, acquired with ∼350 projections (CBCT org ), were retrospectively under-sampled to 25% dose images (CBCT LD ) with only ∼90 projections and reconstructed using Feldkamp–Davis–Kress. We adapted a cycleGAN including shape loss to translate CBCT LD into planning CT (pCT) equivalent images (CBCT LD_GAN ). An alternative cycleGAN with a generator residual connection was implemented to improve anatomical fidelity (CBCT LD_ResGAN ). Unpaired 4-fold cross-validation (33 patients) was performed to allow using the median of 4 models as output. Deformable image registration was used to generate virtual CTs (vCT) for Hounsfield units (HU) accuracy evaluation on 8 additional test patients. Volumetric modulated arc therapy plans were optimized on vCT, and recalculated on CBCT LD_GAN and CBCT LD_ResGAN to determine dose calculation accuracy. CBCT LD_GAN , CBCT LD_ResGAN and CBCT org were registered to pCT and residual shifts were analyzed. Bladder and rectum were manually contoured on CBCT LD_GAN , CBCT LD_ResGAN and CBCT org and compared in terms of Dice similarity coefficient (DSC), average and 95th percentile Hausdorff distance (HD avg , HD 95 ). The mean absolute error decreased from 126 HU for CBCT LD to 55 HU for CBCT LD_GAN and 44 HU for CBCT LD_ResGAN . For PTV, the median differences of D 98% , D 50% and D 2% comparing both CBCT LD_GAN to vCT were 0.3%, 0.3%, 0.3%, and comparing CBCT LD_ResGAN to vCT were 0.4%, 0.3% and 0.4%. Dose accuracy was high with both 2% dose difference pass rates of 99% (10% dose threshold). Compared to the CBCT org -to-pCT registration, the majority of mean absolute differences of rigid transformation parameters were less than 0.20 mm/0.20°. For bladder and rectum, the DSC were 0.88 and 0.77 for CBCT LD_GAN and 0.92 and 0.87 for CBCT LD_ResGAN compared to CBCT org , and HD avg were 1.34 mm and 1.93 mm for CBCT LD_GAN , and 0.90 mm and 1.05 mm for CBCT LD_ResGAN . The computational time was ∼2 s per patient. This study investigated the feasibility of adapting two cycleGAN models to simultaneously remove under-sampling artifacts and correct image intensities of 25% dose CBCT images. High accuracy on dose calculation, HU and patient alignment were achieved. CBCT LD_ResGAN achieved better anatomical fidelity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spiral Cone-Beam Computed TomographyRadiotherapy, Intensity-ModulatedMaleHumansProstateRadiotherapy DosageRetrospective StudiesFeasibility StudiesRadiotherapy Planning, Computer-AssistedCone-Beam Computed TomographyImage Processing, Computer-Assisted

Stichwörter der Autor:innen

Low dose CBCTadaptive therapycycleGAN

Autor:innen und Institutionen

  • Department of Radiation Oncology, University Hospital, LMU Munich, D-81377 Munich, Germany.
  • Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), D-85748 Garching, Germany.
  • German Cancer Consortium (DKTK), D-81377 Munich, Germany.

ORCID-Profile: Y Chan, G Landry

Förderung

  • Research Training Group GRK 2274
  • Deutsche Forschungsgemeinschaft

Zitieren

APA

Chan, Y., Li, M., Parodi, K., Belka, C., Landry, G., & Kurz, C. (2023). Feasibility of CycleGAN enhanced low dose CBCT imaging for prostate radiotherapy dose calculation. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/acccce

Vancouver

Chan Y, Li M, Parodi K, Belka C, Landry G, Kurz C. Feasibility of CycleGAN enhanced low dose CBCT imaging for prostate radiotherapy dose calculation. Physics in Medicine & Biology. 2023. doi:10.1088/1361-6560/acccce

BibTeX
@article{Chan2023,
  author = {Chan, Y and Li, M and Parodi, K and Belka, C and Landry, G and Kurz, C},
  title = {Feasibility of CycleGAN enhanced low dose CBCT imaging for prostate radiotherapy dose calculation},
  journal = {Physics in Medicine & Biology},
  year = {2023},
  doi = {10.1088/1361-6560/acccce}
}
Kostenlos starten →