Vergleichsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 21.10.2026. Verfasst von Yingjie Song und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, National Cancer Center, National Clinical Research Center for Cancer, Cancer Hospital, Chinese Academy of Medical S…. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated, Organs at Risk, Algorithms. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Lattice Radiation Therapy (LRT) is characterized by its 3D‐mouldated spatial dose distribution of vertices inside the lattice volume with high peak‐to‐valley dose ratio (PVDR) for enhancing tumor control and reducing normal tissue toxicity. While face‐centered cubic (FCC) and hexagonal close‐packed (HCP), both achieving maximum spatial packing density, have been used for vertex placement, a direct comparative analysis of their dosimetric performance is lacking.

Purpose

This study aimed to systematically compare FCC and HCP methods for vertex placement under identical conditions to determine which yields superior dosimetric outcomes, specifically regarding the peak‐to‐valley dose ratio (PVDR), and to provide data supporting the standardization of LRT planning. Materials and methods This study was retrospectively conducted on 10 patients with large gross tumor volumes (GTV) (GTV; median [IQR] GTV volume: 916.59[609.37] cm 3 ). For each patient, an identical inward margin was applied to the GTV to create the lattice volume for placing LRT vertices. Within this lattice volume, two sets of spherical vertices were generated: one arranged in a HCP lattice and the other in a FCC lattice, both vertices of same diameter. The initial diameter and volume of vertices were determined based on GTV volume. Vertex positions were optimized using an Adaptive Simulated Annealing (ASA) algorithm to maximize inter‐vertex distance, with the total volume of all vertices constrained to approximately 1% of the GTV. All plans were optimized using identical dose‐volume objectives. Plan quality was evaluated using GTV dose metrics (D 5 %, D 10 %, D 50 %, D 90 %, D mean , V 50 %), normal tissue mean dose (NT D mean ), maximum point doses (D max ) to serial organs at risk and PVDR defined by both GTVD 10 /D 90 and lattice volume D 10 /D 90 ratios.

Results

Vertex parameters (number, volume, spacing) showed no significant difference between Plan_FCC and Plan_HCP ( P > 0.05). Dosimetric analysis revealed a statistically significant increase in PVDR (lattice volume D 10 /D 90 ) for Plan_FCC compared to Plan_HCP (median [IQR]: 6.95 [3.38] vs. 4.48 [2.00], p = 0.019). No other evaluated metrics demonstrated significant differences, including other GTV metrics NT Dmean or the maximum point doses to serial OARs.

Conclusions

Under matched radiation delivery technique, geometric constraints and identical dose‐volume objectives, the FCC vertex arrangement yields a statistically significantly higher peak‐to‐valley dose ratio (lattice volume D 10 /D 90 ), compared to the HCP arrangement, without compromising other dosimetric indices. This finding suggests that FCC may be a preferred starting configuration for LRT vertex placement in large tumors and we recommend that the FCC arrangement be prioritized in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedRadiotherapy, Intensity-ModulatedOrgans at RiskAlgorithmsNeoplasmsHumansRadiotherapy DosageRetrospective StudiesPrognosis

Stichwörter der Autor:innen

close‐packing arrangementsface‐centered cubic (FCC)hexagonal close‐packed (HCP)lattice radiation therapy (LRT)peak‐to‐valley dose ratio (PVDR)vertices arrangement

Autor:innen und Institutionen

  • Department of Radiation Oncology, National Cancer Center, National Clinical Research Center for Cancer, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Song, Y., Ma, P., & Dai, J. (2026). Comparison of two close‐packing methods for vertex placement in lattice radiotherapy (LRT). Journal of Applied Clinical Medical Physics, 27(11). https://doi.org/10.1002/acm2.70850

Vancouver

Song Y, Ma P, Dai J. Comparison of two close‐packing methods for vertex placement in lattice radiotherapy (LRT). Journal of Applied Clinical Medical Physics. 2026;27(11). doi:10.1002/acm2.70850

BibTeX
@article{Song2026,
  author = {Song, Yingjie and Ma, Pan and Dai, Jianrong},
  title = {Comparison of two close‐packing methods for vertex placement in lattice radiotherapy (LRT)},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  volume = {27},
  number = {11},
  doi = {10.1002/acm2.70850}
}
Kostenlos starten →