Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 08.07.2026. Verfasst von Grace Chang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA. Hauptthemen laut MEDLINE: Radiosurgery, Radiotherapy Planning, Computer-Assisted, Lung Neoplasms, Coronary Vessels. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The left anterior descending (LAD) coronary artery is a critical organ‐at‐risk in thoracic radiotherapy. In thoracic stereotactic body radiation therapy (SBRT), sharp dose gradients and poor LAD contrast on 4DCT scans introduce uncertainty in LAD dose assessment.

Methods

We evaluated the performance of an AI‐generated LAD region structure as a surrogate for manual LAD contours in early‐stage NSCLC. We used deep inspiration breath hold (DIBH) scans from 49 patients with manually delineated LADs; planning risk volume contours were expanded by 3 mm. Then, 96 lung SBRT dose maps were registered by matching the left anterior portion of the heart contours. Dice similarity coefficient (DSC), inclusion ratios (IR), dose–volume histogram (DVH) metrics, linear regression, and linear mixed models were used to compare the structures. The correlation of the AI LAD region and LAD dose to mean heart dose (MHD) was assessed.

Results

The AI LAD region showed strong correlation with manual LAD contours for maximum dose (D1%, R 2 = 0.93) and volume receiving ≥10 Gy (V10Gy, R 2 = 0.81). The planning risk volume also demonstrated high correlation to the AI LAD region. MHD was a poor predictor of LAD dose ( R 2 ≈0.4). Additional dose metric correlations were assessed.

Discussion

To investigate dose volume effects to the LAD during radiotherapy for stage I NSCLC, a robust segmentation paradigm must be established. It must be easily implementable on typical imaging acquired during treatment, with an emphasis on clinical translatability. Our model has shown that the AI LAD region has a strong correlation with LAD dose under typical lung SBRT doses and supports its use for further investigation into LAD dose volume constraints during lung SBRT.

Conclusion

AI LAD region provides a clinically feasible and scalable alternative to manual LAD contouring for dose estimation in lung SBRT. Its strong correlation with key dose metrics validates its use in large‐scale retrospective and prospective studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiosurgeryRadiotherapy Planning, Computer-AssistedLung NeoplasmsCoronary VesselsOrgans at RiskCarcinoma, Non-Small-Cell LungArtificial IntelligenceImage Processing, Computer-AssistedHumansRadiotherapy DosageFour-Dimensional Computed TomographyRadiotherapy, Intensity-Modulated

Stichwörter der Autor:innen

AI segmentationLung SBRTleft descending arterymean heart dose

Autor:innen und Institutionen

  • Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA.

Zitieren

APA

Chang, G., Chen, Q., Tao, R., Zhu, L., Rong, Y., & Yu, N. Y. (2026). AI‐surrogate structure and dose correlation for left anterior descending artery in lung stereotactic body radiotherapy. Journal of Applied Clinical Medical Physics, 27(7). https://doi.org/10.1002/acm2.70703

Vancouver

Chang G, Chen Q, Tao R, Zhu L, Rong Y, Yu NY. AI‐surrogate structure and dose correlation for left anterior descending artery in lung stereotactic body radiotherapy. Journal of Applied Clinical Medical Physics. 2026;27(7). doi:10.1002/acm2.70703

BibTeX
@article{Chang2026,
  author = {Chang, Grace and Chen, Quan and Tao, Randa and Zhu, Libing and Rong, Yi and Yu, Nathan Y},
  title = {AI‐surrogate structure and dose correlation for left anterior descending artery in lung stereotactic body radiotherapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  volume = {27},
  number = {7},
  doi = {10.1002/acm2.70703}
}
Kostenlos starten →