PCA‐based respiratory motion modeling for individualized PTV margin optimization in NSCLC radiotherapy
Journal of Applied Clinical Medical Physics · 2026-06 · 27 (6)
DOI: 10.1002/acm2.70652 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 07.06.2026. Verfasst von Huy Dang Quang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiotherapy, Institute of Oncology and Nuclear Medicine, Military Hospital 175, Ho Chi Minh City, Vietnam. Hauptthemen laut MEDLINE: Lung Neoplasms, Carcinoma, Non-Small-Cell Lung, Radiotherapy Planning, Computer-Assisted, Four-Dimensional Computed Tomography. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Respiratory motion remains a major challenge in radiotherapy for non‐small cell lung cancer (NSCLC), often requiring a balance between target coverage and normal tissue sparing.
Introduction
This study aimed to develop and validate a clinically implementable, individualized PTV margin strategy by integrating principal component analysis (PCA) with key clinical predictors.
Methods
A cohort of 61 NSCLC patients (Stage III) underwent 4DCT simulation. 4DCT datasets were used both for motion modeling and as a reference planning approach (ITV‐based). The proposed method was compared against conventional 3DCT and 4DCT‐based plans. PCA was applied to the deformable vector fields to extract dominant motion modes and quantify directional amplitudes ( A mean ). Clinical correlations with tumor motion were assessed. An individualized margin recipe, was implemented, incorporating a Location Factor and a T stage Factor () derived from cohort‐specific data. Dosimetric plans (3DCT, Individualized‐3DCT and 4DCT) were compared using QUANTEC constraints.
Results
Tumor location ( p = 0.007) and T stage ( p = 0.04) were identified as significant predictors of S–I motion amplitude. Middle/lower lobe tumors and early T1–T2 stages exhibited higher mobility (≥ 15 mm). By applying adaptive weighting factors (= 1.2 for lower lobes; = 0.9 for T3–T4), the individualized 3D plans achieved a significant reduction in PTV volume compared to 3D plans (410.0 ± 170.0 cm 3 vs. 460.2 ± 179.1 cm 3 , p = 0.002). The individualized margin approach reduced lung dose compared with conventional 3DCT planning (V20: 30.0% vs. 40.5%), while remaining comparable to the 4DCT‐based reference plan (28.9%). Other OARs remained within tolerance limits.
Conclusions
Integrating PCA‐derived motion with clinical weighting provides a practical framework for individualized margin design, improving lung sparing while maintaining target coverage.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiotherapy, Institute of Oncology and Nuclear Medicine, Military Hospital 175, Ho Chi Minh City, Vietnam.
- Department of Nuclear Physics, Faculty of Physics and Engineering Physics, University of Sciences, Ho Chi Minh City, Vietnam.
- Vietnam National University, Ho Chi Minh City, Vietnam.
ORCID-Profile: Huy Dang Quang
Zitieren
APA
Quang, H. D., Thanh, C. N., Kieu, T. H. T., & Van, T. C. (2026). PCA‐based respiratory motion modeling for individualized PTV margin optimization in NSCLC radiotherapy. Journal of Applied Clinical Medical Physics, 27(6). https://doi.org/10.1002/acm2.70652
Vancouver
Quang HD, Thanh CN, Kieu THT, Van TC. PCA‐based respiratory motion modeling for individualized PTV margin optimization in NSCLC radiotherapy. Journal of Applied Clinical Medical Physics. 2026;27(6). doi:10.1002/acm2.70652
BibTeX
@article{Quang2026,
author = {Quang, Huy Dang and Thanh, Cong Nguyen and Kieu, Trang Hoang Thi and Van, Tao Chau},
title = {PCA‐based respiratory motion modeling for individualized PTV margin optimization in NSCLC radiotherapy},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
volume = {27},
number = {6},
doi = {10.1002/acm2.70652}
}
EUVIMED