A dosimetric analysis of a rotating gamma ray system and volumetric modulated arc therapy in retrospective replanning for primary liver cancer
Journal of Applied Clinical Medical Physics · 2026-06 · 27 (6)
DOI: 10.1002/acm2.70581 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 15.06.2026. Verfasst von Jiarui Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Chifeng Tumor Hospital, Inner Mongolia Autonomous Region, Chifeng, China. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Radiotherapy Planning, Computer-Assisted, Liver Neoplasms, Gamma Rays. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: 2025 Special Research Project on Tumor Immunity and Targeted Therapy, Wu Jieping Medical Foundation, Chifeng Natural Science Research Project.
Abstract (Originalsprache)
Background
This study is a retrospective replanning study. For primary liver cancer, radiotherapy is vital for inoperable patients; however, dosimetric data comparing the rotating gamma ray system (RGS) and volumetric modulated arc therapy (VMAT) remains scarce, complicating clinical technique selection. Notably, RGS refers to a body gamma ray platform designed for extracranial stereotactic body radiotherapy (SBRT) — this is distinct from the “Gamma Knife” system, which is specifically dedicated to intracranial radiosurgery.
Purpose
To compare the dosimetric differences between RGS and VMAT techniques in the radiotherapy of primary liver cancer.
Methods
30 patients with primary liver cancer, underwent both RGS and VMAT planning. Analyzed planning target volume (PTV) parameters: coverage (Target Coverage Index, TCI), max/mean/min dose (D max /D mean /D min ), conformity (Conformity Index, CI), homogeneity (Homogeneity Index, HI), gradient index (Gradient Index, GI). Evaluated liver doses: D mean , V 20 , V 5 .
Results
In this dosimetric comparison of 30 primary liver cancer patients, RGS plans demonstrated significantly higher maximum tumor dose (D max : 10253 ± 196 cGy vs. VMAT: 6807 ± 315 cGy; P < 0.001), mean tumor dose (D mean median [IQR]: RGS: 7410 cGy [7222–7493] vs. VMAT: 5780 cGy [5675–5870]; P < 0.001), and target coverage (median [IQR]: RGS: 100% [99–100] vs. VMAT: 98% [98–98]; P < 0.001) compared to VMAT plans. RGS also exhibited a steeper dose fall‐off (GI: 3.32 ± 0.37 vs. VMAT: 5.84 ± 1.12; P < 0.001). Conversely, VMAT achieved superior conformity (CI: 0.83 ± 0.06 vs. RGS: 0.63 ± 0.08; P < 0.001), homogeneity (HI: 0.23 ± 0.05 vs. RGS: 0.57 ± 0.05; P < 0.001), and significantly reduced low‐dose liver irradiation (V 5 : 23.7% ± 10.2% vs. RGS: 34.4% ± 12.8%; P < 0.001). The mean liver dose was also significantly lower with VMAT (616 ± 253 cGy vs. RGS: 677 ± 314 cGy; P = 0.039). No significant differences were observed in minimum tumor dose (D min ) or liver V 20 .
Conclusions
In radiotherapy for primary liver cancer, the rotating gamma ray system offers the characteristic of highly focused central dose with rapid peripheral dose fall‐off, ensuring high tumor dose while better protecting adjacent liver tissues. VMAT provides superior conformity and homogeneity, with better control of the mean liver dose and low‐dose irradiation volumes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Chifeng Tumor Hospital, Inner Mongolia Autonomous Region, Chifeng, China.
ORCID-Profile: Jiarui Zhang
Förderung
- 2025 Special Research Project on Tumor Immunity and Targeted Therapy
- Wu Jieping Medical Foundation
- Chifeng Natural Science Research Project
Zitieren
APA
Zhang, J., Shi, S., Wu, J., Shi, L., Song, L., Yang, M., Yu, H., Zhen, P., & Fang, F. (2026). A dosimetric analysis of a rotating gamma ray system and volumetric modulated arc therapy in retrospective replanning for primary liver cancer. Journal of Applied Clinical Medical Physics, 27(6). https://doi.org/10.1002/acm2.70581
Vancouver
Zhang J, Shi S, Wu J, Shi L, Song L, Yang M, et al. A dosimetric analysis of a rotating gamma ray system and volumetric modulated arc therapy in retrospective replanning for primary liver cancer. Journal of Applied Clinical Medical Physics. 2026;27(6). doi:10.1002/acm2.70581
BibTeX
@article{Zhang2026,
author = {Zhang, Jiarui and Shi, Siming and Wu, Jingran and Shi, Lei and Song, Liying and Yang, Meng and Yu, Huiyang and Zhen, Peng and Fang, Fang},
title = {A dosimetric analysis of a rotating gamma ray system and volumetric modulated arc therapy in retrospective replanning for primary liver cancer},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
volume = {27},
number = {6},
doi = {10.1002/acm2.70581}
}
EUVIMED