Quantification of dose accumulation using deformable image registration: Application in re‐irradiation of liver metastases using robotic radiosurgery

Ahamed Badusha Mohamed Yoosuf iD, Mohd Zahri Abdul Aziz, Mohd Syahir Mansoor, Gokula Kumar Appalanaido, Salem Alshehri, Mamdouh Alqathami

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70278 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Ahamed Badusha Mohamed Yoosuf und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oncology, Ministry of National Guard Health Affairs, Riyadh, Saudi Arabia. Hauptthemen laut MEDLINE: Radiosurgery, Liver Neoplasms, Organs at Risk, Radiotherapy Planning, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study evaluates cumulative dose estimations using deformable image registration (DIR) in robotic stereotactic ablative radiotherapy (SABR)‐based multiple re‐irradiations for liver metastases. It highlights DIR's role and accuracy in adaptive radiotherapy to enhance treatment precision and reduce toxicity. Materials & Methods A retrospective analysis was conducted on 22 patients (age: 42–80, median: 61 years) with liver metastases re‐irradiated using CyberKnife SABR (54 treatments) between June 2016 and February 2024. A comparative analysis of organs‐at‐risk (OAR) volumes was performed using contours derived from DIR and physical summation method to evaluate consistency between the two approaches. Dosimetric analysis involved accumulating doses to organs at risk using physical dose summation and DIR‐based dose summation. To standardize dose assessments, all radiation doses were converted into equivalent doses in 2 Gy fractions (EQD2) and biologically effective doses (BED). The DIR algorithm was quantitatively assessed using similarity indices, including Dice similarity coefficient (DSC) and Jaccard (JD) index.

Results

The findings demonstrated that organs susceptible to motion, such as the liver and large bowel, exhibited greater variability in volume measurements when evaluated using physical summation. A significant reduction in maximum dose for the liver ( p = 0.00) and chest wall ( p = 0.05) was observed under DIR‐based dose accumulation (liver‐83.2 ± 28.0 Gy; chest wall‐66.9 ± 18.6 Gy) compared to physical summation (liver‐123.8 ± 55.6 Gy; chest wall‐82.9 ± 22.4 Gy), suggesting overestimation using physical summation. Among the analyzed structures, DIR showed high spatial accuracy for the heart, liver, and external body with Dice scores > 0.90 and Jaccard indices > 0.84, while lower agreement was noted for deformable organs such as the bowel with Dice scores < 0.43 and Jaccard indices < 0.29.

Conclusions

DIR improved anatomical alignment and provides more anatomically consistent cumulative dose estimation in SABR re‐irradiation, particularly for OARs that are prone to deform. Integrating DIR into adaptive radiotherapy workflows can improve the estimation of dose to OARs while minimizing toxicity risks.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiosurgeryLiver NeoplasmsOrgans at RiskRadiotherapy Planning, Computer-AssistedRobotic Surgical ProceduresRe-IrradiationImage Processing, Computer-AssistedHumansRetrospective StudiesMiddle AgedRadiotherapy DosageAgedFemaleMaleAdultAged, 80 and overRadiotherapy, Intensity-ModulatedAlgorithms

Stichwörter der Autor:innen

deformable image registration (DIR)dose accumulationliver metastasesmultiple re‐irradiationrobotic stereotactic radiosurgery

Autor:innen und Institutionen

  • Department of Oncology, Ministry of National Guard Health Affairs, Riyadh, Saudi Arabia.
  • Clinical Research, King Abdullah International Medical Research Center (KAIMRC), Riyadh, Saudi Arabia.
  • Advanced Management of Liver Malignancies Program, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Penang, Malaysia.
  • Radiotherapy Unit, Pusat Perubatan Universiti Sains Malaysia, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Penang, Malaysia.
  • Nuclear Medicine Unit, Pusat Perubatan Universiti Sains Malaysia, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Penang, Malaysia.
  • Radiological Sciences, King Saud bin Abdulaziz University for Health Sciences, Riyadh, Saudi Arabia.

ORCID-Profile: Ahamed Badusha Mohamed Yoosuf

Zitieren

APA

Mohamed Yoosuf, A. B., Abdul Aziz, M. Z., Mansoor, M. S., Appalanaido, G. K., Alshehri, S., & Alqathami, M. (2025). Quantification of dose accumulation using deformable image registration: Application in re‐irradiation of liver metastases using robotic radiosurgery. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70278

Vancouver

Mohamed Yoosuf AB, Abdul Aziz MZ, Mansoor MS, Appalanaido GK, Alshehri S, Alqathami M. Quantification of dose accumulation using deformable image registration: Application in re‐irradiation of liver metastases using robotic radiosurgery. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70278

BibTeX
@article{MohamedYoosuf2025,
  author = {Mohamed Yoosuf, Ahamed Badusha and Abdul Aziz, Mohd Zahri and Mansoor, Mohd Syahir and Appalanaido, Gokula Kumar and Alshehri, Salem and Alqathami, Mamdouh},
  title = {Quantification of dose accumulation using deformable image registration: Application in re‐irradiation of liver metastases using robotic radiosurgery},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70278}
}