Dosimetric comparison of sequential planning (SP) versus bias dose planning (BDP) in volumetric modulated arc therapy (VMAT)‐based breast radiotherapy boost
Journal of Applied Clinical Medical Physics · 2026-04 · 27 (4)
DOI: 10.1002/acm2.70544 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 15.04.2026. Verfasst von Thirumal Mani und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiations Oncology, All India Institute of Medical Sciences (AIIMS), Bibinagar, Hyderabad, Telangana, India. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated, Organs at Risk, Breast Neoplasms. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aim/purpose This study aims to evaluate and compare the dosimetric parameters of breast cancer radiotherapy plans using Volumetric Modulated Arc Therapy (VMAT), specifically contrasting the use of the bias dose planning (BDP) feature with sequential planning (SP) without bias in the Monaco Treatment Planning System (TPS). Materials and methods A total of twenty left breast carcinoma patients were randomly selected for this study, which followed a two‐phase treatment regimen. In Phase 1, a dose of 40 Gy was delivered using the Elekta Versa HD, and the treatment plans were generated with 6 MV beams in the Monaco TPS using the VMAT technique. Phase 2 involved a sequential boost, delivering an additional 12.5 Gy, also using VMAT. For each patient, two treatment plans were created for Phase 2: one utilizing the BDP feature and the other SP, allowing for a direct dosimetric comparison of target volume, Organ at risk (OAR), normal tissue exposures, conformity index (CI) and Homogeneity index (HI).
Results
Both the BDP and SP achieved comparable target volume coverage, with similar conformity and homogeneity indices. However, BDP demonstrated better sparing of OARs. Specifically, BDP significantly reduced the mean doses to the left lung (1496.4 ± 47.9 cGy vs. 1594 ± 189.3 cGy), right lung (465.9 ± 109.1 cGy vs. 591.6 ± 251.4 cGy), and heart (770.1 ± 232.0 cGy vs. 970.2 ± 65.5 cGy) compared to SP (all p < 0.05). Additionally, volume‐based metrics, including V20 and V5Gy, consistently favored BDP. There was no substantial difference in the absolute volumes (cc) of the Body‐PTV structure receiving 10% to 90% of the prescription dose between the BDP and SP plans, and the differences were not statistically significant ( P ≥ 0.05). These findings underscore the dosimetric advantage of BDP in minimizing radiation exposure to critical structures without compromising target coverage.
Conclusion
The integration of the bias dose feature in VMAT‐based breast cancer radiotherapy planning offers dosimetric advantages by improving sparing of critical organs without compromising target coverage or plan quality. This study highlights the importance of incorporating bias dose planning (BDP) in multiphase breast radiotherapy, especially when sequential boosts are required and supports its suitability for adoption in routine clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiations Oncology, All India Institute of Medical Sciences (AIIMS), Bibinagar, Hyderabad, Telangana, India.
- Department of Radiotherapy, Manipal Hospitals, Bengaluru, Karnataka, India.
ORCID-Profile: Thirumal Mani, Ajay Kumar Kondeti
Zitieren
APA
Mani, T., Duraikannu, P., Ramalingam, C., & Kondeti, A. K. (2026). Dosimetric comparison of sequential planning (SP) versus bias dose planning (BDP) in volumetric modulated arc therapy (VMAT)‐based breast radiotherapy boost. Journal of Applied Clinical Medical Physics, 27(4). https://doi.org/10.1002/acm2.70544
Vancouver
Mani T, Duraikannu P, Ramalingam C, Kondeti AK. Dosimetric comparison of sequential planning (SP) versus bias dose planning (BDP) in volumetric modulated arc therapy (VMAT)‐based breast radiotherapy boost. Journal of Applied Clinical Medical Physics. 2026;27(4). doi:10.1002/acm2.70544
BibTeX
@article{Mani2026,
author = {Mani, Thirumal and Duraikannu, Palanivelu and Ramalingam, Chandramouli and Kondeti, Ajay Kumar},
title = {Dosimetric comparison of sequential planning (SP) versus bias dose planning (BDP) in volumetric modulated arc therapy (VMAT)‐based breast radiotherapy boost},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
volume = {27},
number = {4},
doi = {10.1002/acm2.70544}
}
EUVIMED