Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Giulianne Rivelli Rodrigues Zaratim und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, CONFIAR Radiotherapy, Goiânia, Goiás, Brazil. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated, Breast Neoplasms, Radiotherapy Dosage. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purposes This study aimed to develop and validate algorithms for automating intensity modulated radiation therapy (IMRT) planning in breast cancer patients, with a focus on patient anatomical characteristics. Material and Methods We retrospectively selected 400 breast cancer patients without lymph node involvement for automated treatment planning. Automation was achieved using the Eclipse Scripting Application Programming Interface (ESAPI) integrated into the Eclipse Treatment Planning System. We employed three beam insertion geometries and three optimization strategies, resulting in 3600 plans, each delivering a 40.05 Gy dose in 15 fractions. Gantry angles in the tangent fields were selected based on a criterion involving the minimum intersection area between the Planning Target Volume (PTV) and the ipsilateral lung in the Beam's Eye View projection. ESAPI was also used to gather patient anatomical data, serving as input for Random Forest models to select the optimal plan. The Random Forest classification considered both beam insertion geometry and optimization strategy. Dosimetric data were evaluated in accordance with the Radiation Therapy Oncology Group (RTOG) 1005 protocol.
Results
Overall, all approaches generated high‐quality plans, with approximately 94% meeting the acceptable dose criteria for organs at risk and/or target coverage as defined by RTOG guidelines. Average automated plan generation time ranged from 6 min and 37 s to 9 min and 22 s, with the mean time increasing with additional fields. The Random Forest approach did not successfully enable automatic planning strategy selection. Instead, our automated planning system allows users to choose from the tested geometry and strategy options.
Conclusions
Although our attempt to correlate patient anatomical features with planning strategy using machine learning tools was unsuccessful, the resulting dosimetric outcomes proved satisfactory. Our algorithm consistently produced high‐quality plans, offering significant time and efficiency advantages.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, CONFIAR Radiotherapy, Goiânia, Goiás, Brazil.
- Department of Radiation Oncology, University Hospital of Brasilia, Brasilia, Federal District, Brazil.
ORCID-Profile: Giulianne Rivelli Rodrigues Zaratim, Ricardo Gomes Dos Reis, Marcos Antônio Dos Santos, Nathalya Ala Yagi, Luis Felipe Oliveira E Silva
Zitieren
APA
Zaratim, G. R. R., Dos Reis, R. G., Dos Santos, M. A., Yagi, N. A., & Oliveira E Silva, L. F. (2024). Automated treatment planning for whole breast irradiation with individualized tangential IMRT fields. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14361
Vancouver
Zaratim GRR, Dos Reis RG, Dos Santos MA, Yagi NA, Oliveira E Silva LF. Automated treatment planning for whole breast irradiation with individualized tangential IMRT fields. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14361
BibTeX
@article{Zaratim2024,
author = {Zaratim, Giulianne Rivelli Rodrigues and Dos Reis, Ricardo Gomes and Dos Santos, Marcos Antônio and Yagi, Nathalya Ala and Oliveira E Silva, Luis Felipe},
title = {Automated treatment planning for whole breast irradiation with individualized tangential IMRT fields},
journal = {Journal of Applied Clinical Medical Physics},
year = {2024},
doi = {10.1002/acm2.14361}
}
EUVIMED