EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of automated whole breast 3D planning with tangential fields

Christopher Busch, Ping Xia, Chirag Shah, Rahul Tendulkar, Young-Bin Cho iD

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70415 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Christopher Busch und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio, USA. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Breast Neoplasms, Organs at Risk, Radiotherapy, Intensity-Modulated. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives/Purposes Whole breast 3D treatment planning with tangential fields often requires multiple manual adjustments, leading to inefficiency and variability. This study presents and evaluates an in‐house developed automated script designed to improve planning efficiency and consistency for breast radiotherapy using tangential fields. Materials/Methods 19 breast cancer patients from an IRB‐approved study were selected. The automated script was developed to generate beam segments through a three‐step process, (1) verification of field setup, and generation of breast planning target volume (PTV), (2) duplication of the clinical plan with open tangents and (3) automatic generation of beam segments to reduce hotspot iteratively. Plans produced by the automated script (AS) were compared to the manually optimized (MO) clinical plans using eight evaluation metrics: V16Gy of the ipsilateral lung, mean heart dose, V90%, V95% (dose coverage), V105% (hotspot) of PTV, number of segments, MU (monitor unit) weighted segment area, and total MUs. A statistical analysis was performed using the Wilcoxon signed‐rank test.

Results

Four of the eight metrics showed statistical differences. For MO and AS plans, the average ± SD of ipsilateral lung 16 Gy was 15.05% ± 3.27% vs. 15.10% ± 3.26% ( p = 0.04) while the mean heart dose was 0.87 Gy ± 0.52 Gy, vs. 0.87 Gy ± 0.53 Gy ( p = 0.68). With regards to homogeneity and coverage, the PTV V105% were 2.0% ± 5.0% and 3.7% ± 6.4% ( p = 0.03) while the PTV V90% were 98.8% ± 1.5% and 99.1% ± 0.9% ( p = 0.14), V95% were 92.0% ± 4.4% and 92.4% ± 3.2% ( p = 0.63) respectively. The number of segments and MU weighted segment areas were 7.3 ± 1.3 and 10.9 ± 1.9 ( p < 0.001); 268.2 ± 96.6 cm 2 and 262.6 ± 92.9 cm 2 ( p < 0.001). The total MUs was 351.7 ± 99.0 and 354.7 ± 101.2 ( p = 0.05).

Conclusion

The automated script successfully generated high‐quality tangential breast plans that met all clinical constraints. It significantly improved consistency while maintaining clinical acceptability, demonstrating potential for broader use in automated 3D planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedBreast NeoplasmsOrgans at RiskRadiotherapy, Intensity-ModulatedImaging, Three-DimensionalHumansRadiotherapy DosageFemaleAlgorithmsAutomation

Stichwörter der Autor:innen

automated forward planningautomated planning scriptautomated segment generationplan automationtangential breast planningwhole breast irradiation

Autor:innen und Institutionen

  • Department of Radiation Oncology, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio, USA.
  • Department of Radiation Oncology, Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA.
  • Department of Radiation Oncology, Allegheny Health Network, Pittsburgh, Pennsylvania, USA.
  • Department of Biomedical Engineering, Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA.

ORCID-Profile: Young-Bin Cho

Zitieren

APA

Busch, C., Xia, P., Shah, C., Tendulkar, R., & Cho, Y. B. (2025). Development of automated whole breast 3D planning with tangential fields. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70415

Vancouver

Busch C, Xia P, Shah C, Tendulkar R, Cho YB. Development of automated whole breast 3D planning with tangential fields. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70415

BibTeX
@article{Busch2025,
  author = {Busch, Christopher and Xia, Ping and Shah, Chirag and Tendulkar, Rahul and Cho, Young-Bin},
  title = {Development of automated whole breast 3D planning with tangential fields},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70415}
}