EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Analysis of the effect of dual reference lines on first positioning accuracy in intensity‐modulated radiotherapy for cervical cancers

Jinjin Feng, Zaichun Shang, Binbin Ge iD, Kaiyue Chu, Jianhua Jin iD, Jingjing Shao, Xinhua Zhang

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70342 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Jinjin Feng und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anatomy, Medical School of Nantong University, Nantong, China. Hauptthemen laut MEDLINE: Uterine Cervical Neoplasms, Radiotherapy, Intensity-Modulated, Radiotherapy Planning, Computer-Assisted, Patient Positioning. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Special Research Project of the Health Commission of Nantong.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To investigate the use of dual‐reference lines to reduce positioning errors and optimize modified planning target volume (MPTV) in volume modulated arc therapy (VMAT) for cervical cancers.

Methods

Thirty‐seven patients with FIGO stage IIB‐IVA cervical cancer and no distant metastasis, who underwent radiotherapy in a tertiary hospital from June 15 2022 to September 15 2023, were selected and randomly divided into dual positioning reference line group (dual‐line group, 21 cases) and single positioning reference line group (single‐line group, 16 cases). A single reference line was made in pelvic region in single‐line group, while dual reference lines were made in stable abdominopelvic region in dual‐line group. The cone‐beam computed tomography (CBCT) was conducted to determine the positioning errors and calculate MPTV.

Results

Linear error in Y direction, rotational errors in the rotation around Y ‐axis ( RY )/ Z ‐axis ( RZ ) (0.27 ± 0.12 cm, 0.60 ± 0.42°, 0.48 ± 0.44°) in dual‐line group were smaller than those (0.35 ± 0.22 cm, 0.78 ± 0.45°, 0.85 ± 0.66°) in single‐line group ( p < 0.05). The thresholds of 0.4 cm and 1.4° were set as the boundary values for linear and rotational errors, respectively. There were significant statistical differences in the distribution of positioning errors in the six directions between the two groups ( p < 0.001), with higher positioning error rates in the Y (77.78%), RY (41.46%), and RZ (53.66%) directions, respectively. Median total positioning time in dual‐line group (8.27 min, interquartile rang [IQR]: 7.65–8.63) was shorter than that (8.75 min, IQR: 7.89–9.45) in single‐line group (Z = 3.53998, p < 0.001). MPTVs in X , Y , and Z directions (0.25, 0.37, and 0.10 cm) in dual‐line group were smaller than those (0.31, 0.56, and 0.11 cm) in single‐line group.

Conclusion

Dual‐reference lines improve positioning accuracy, reduce MPTV, and enhance efficiency in VMAT for middle and advanced cervical cancers, offering a clinically practical solution for precision radiotherapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Uterine Cervical NeoplasmsRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedPatient PositioningCone-Beam Computed TomographyRadiotherapy Setup ErrorsHumansFemaleRadiotherapy DosageMiddle AgedOrgans at RiskAdultRetrospective StudiesAged

Stichwörter der Autor:innen

cervical cancerdual positioning reference linemodified planning target volumepositioning errorradiotherapy

Autor:innen und Institutionen

  • Department of Anatomy, Medical School of Nantong University, Nantong, China.
  • Department of Radiotherapy, Nantong Tumor Hospital, Tumor Hospital Affiliated to Nantong University, Nantong, China.
  • School of Electronic Science and Engineering, Nanjing University, Nanjing, China.

ORCID-Profile: Binbin Ge, Jianhua Jin

Förderung

  • National Natural Science Foundation of China
  • Special Research Project of the Health Commission of Nantong

Zitieren

APA

Feng, J., Shang, Z., Ge, B., Chu, K., Jin, J., Shao, J., & Zhang, X. (2025). Analysis of the effect of dual reference lines on first positioning accuracy in intensity‐modulated radiotherapy for cervical cancers. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70342

Vancouver

Feng J, Shang Z, Ge B, Chu K, Jin J, Shao J, et al. Analysis of the effect of dual reference lines on first positioning accuracy in intensity‐modulated radiotherapy for cervical cancers. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70342

BibTeX
@article{Feng2025,
  author = {Feng, Jinjin and Shang, Zaichun and Ge, Binbin and Chu, Kaiyue and Jin, Jianhua and Shao, Jingjing and Zhang, Xinhua},
  title = {Analysis of the effect of dual reference lines on first positioning accuracy in intensity‐modulated radiotherapy for cervical cancers},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70342}
}
Kostenlos starten →