EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluating the dosimetric impact of deep‐learning‐based auto‐segmentation in prostate cancer radiotherapy: Insights into real‐world clinical implementation and inter‐observer variability

Najmeh Arjmandi, Mohammad Amin Mosleh-Shirazi, Shokoufeh Mohebbi, Shahrokh Nasseri, Alireza Mehdizadeh, Zohreh Pishevar, Sare Hosseini, Amin Amiri Tehranizadeh, Mehdi Momennezhad iD

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.14569 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Najmeh Arjmandi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran. Hauptthemen laut MEDLINE: Deep Learning, Radiotherapy Planning, Computer-Assisted, Prostatic Neoplasms, Organs at Risk. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Mashhad University of Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to investigate the dosimetric impact of deep‐learning‐based auto‐contouring for clinical target volume (CTV) and organs at risk (OARs) delineation in prostate cancer radiotherapy planning. Additionally, we compared the geometric accuracy of auto‐contouring system to the variability observed between human experts.

Methods

We evaluated 28 planning CT volumes, each with three contour sets: reference original contours (OC), auto‐segmented contours (AC), and expert‐defined manual contours (EC). We generated 3D‐CRT and intensity‐modulated radiation therapy (IMRT) plans for each contour set and compared their dosimetric characteristics using dose‐volume histograms (DVHs), homogeneity index (HI), conformity index (CI), and gamma pass rate (3%/3 mm).

Results

The geometric differences between automated contours and both their original manual reference contours and a second set of manually generated contours are smaller than the differences between two manually contoured sets for bladder, right femoral head (RFH), and left femoral head (LFH) structures. Furthermore, dose distribution accuracy using planning target volumes (PTVs) derived from automatically contoured CTVs and auto‐contoured OARs demonstrated consistency with plans based on reference contours across all evaluated cases for both 3D‐CRT and IMRT plans. For example, in IMRT plans, the average D 95 for PTVs was 77.71 ± 0.53 Gy for EC plans, 77.58 ± 0.69 Gy for OC plans, and 77.62 ± 0.38 Gy for AC plans. Automated contouring significantly reduced contouring time, averaging 0.53 ± 0.08 min compared to 24.9 ± 4.5 min for manual delineation.

Conclusion

Our automated contouring system can reduce inter‐expert variability and achieve dosimetric accuracy comparable to gold standard reference contours, highlighting its potential for streamlining clinical workflows. The quantitative analysis revealed no consistent trend of increasing or decreasing PTVs derived from automatically contoured CTVs and OAR doses due to automated contours, indicating minimal impact on treatment outcomes. These findings support the clinical feasibility of utilizing our deep‐learning‐based auto‐contouring model for prostate cancer radiotherapy planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningRadiotherapy Planning, Computer-AssistedProstatic NeoplasmsOrgans at RiskRadiotherapy, Intensity-ModulatedRadiometryTomography, X-Ray ComputedProstateHumansMaleImaging, Three-DimensionalFeasibility StudiesRetrospective StudiesRadiotherapy DosageObserver Variation

Stichwörter der Autor:innen

auto‐contouringdeep learninginter‐observer variabilityprostate segmentationradiotherapy treatment planning

Autor:innen und Institutionen

  • Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Physics Unit, Department of Radio-Oncology, Shiraz University of Medical Sciences, Shiraz, Iran.
  • Ionizing and Non-Ionizing Radiation Protection Research Center, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran.
  • Medical Physics Department, Reza Radiation Oncology Center, Mashhad, Iran.
  • Medical Physics Research Center, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Department of Radiation Oncology, Mashhad University of Medical Sciences, Mashhad, Iran.

ORCID-Profile: Mehdi Momennezhad

Förderung

  • Mashhad University of Medical Sciences

Zitieren

APA

Arjmandi, N., Mosleh-Shirazi, M. A., Mohebbi, S., Nasseri, S., Mehdizadeh, A., Pishevar, Z., Hosseini, S., Tehranizadeh, A. A., & Momennezhad, M. (2025). Evaluating the dosimetric impact of deep‐learning‐based auto‐segmentation in prostate cancer radiotherapy: Insights into real‐world clinical implementation and inter‐observer variability. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14569

Vancouver

Arjmandi N, Mosleh-Shirazi MA, Mohebbi S, Nasseri S, Mehdizadeh A, Pishevar Z, et al. Evaluating the dosimetric impact of deep‐learning‐based auto‐segmentation in prostate cancer radiotherapy: Insights into real‐world clinical implementation and inter‐observer variability. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.14569

BibTeX
@article{Arjmandi2025,
  author = {Arjmandi, Najmeh and Mosleh-Shirazi, Mohammad Amin and Mohebbi, Shokoufeh and Nasseri, Shahrokh and Mehdizadeh, Alireza and Pishevar, Zohreh and Hosseini, Sare and Tehranizadeh, Amin Amiri and Momennezhad, Mehdi},
  title = {Evaluating the dosimetric impact of deep‐learning‐based auto‐segmentation in prostate cancer radiotherapy: Insights into real‐world clinical implementation and inter‐observer variability},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.14569}
}
Kostenlos starten →