Clinical evaluation and regression test of a commercial deep‐learning auto‐segmentation model

Roya Barati iD, Jingwei Duan, Song Gao iD, Yao Zhao, Xinru Chen, Cenji Yu, Zhan Xu, Moghadaseh Khaleghibizaki, Fredrik Lofman, Jared Ohrt iD, Laurence Court, Peter Balter und 1 weitere

Journal of Applied Clinical Medical Physics · 2026

DOI: 10.1002/acm2.70824 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Roya Barati und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Deep Learning, Software, Tomography, X-Ray Computed. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Commercial deep‐learning segmentation (DLS) tools are increasingly used in clinical practice. Software updates may alter segmentation performance, highlighting the need for systematic clinical evaluation before implementation.

Purpose

This study presents our experience in clinically evaluating and regression‐testing a RayStation DLS model with the aim of guiding commissioning and routine quality assurance of commercial DLS tools in clinical environments.

Methods

U‐Net DLS model for normal‐tissue structures, originally commissioned in RayStation version 11B, was regression‐tested after upgrading to 2024A. Previously commissioned CT datasets for head and neck ( n = 18), thorax ( n = 18), male pelvis ( n = 18), and breast ( n = 21) were re‐evaluated in RayStation 2024A for regression testing following the software upgrade, while 20 new abdominal cases were included for initial commissioning. Clinical segmentations served as the reference standard. Geometric performance was evaluated using Dice Similarity Coefficient (DSC), 95% Hausdorff Distance (HD95), and Mean Surface Distance (MSD). Dosimetric evaluation used the original clinical treatment plans to compare Dmean and Dmax between DLS and clinical contours, normalized to prescription dose; breast was excluded from dosimetric analysis because its DLS model was not commissioned for clinical use.

Results

Regression testing showed that, in comparison with the previously commissioned data, mean [± standard deviation (SD)] DSC values were 0.81 ± 0.09 for the head and neck, 0.84 ± 0.13 for the thorax, and 0.89 ± 0.06 for male pelvis. Corresponding MSD values were 0.83 ± 0.34 mm, 2.47 ± 1.81 mm, and 1.76 ± 0.68 mm; and HD95 values were 4.75 ± 2.38 mm, 8.45 ± 3.38 mm, and 13.21 ± 7.05 mm. Significant paired differences between versions were limited to selected structures, including the mandible, cochlea, and eye in head and neck; lungs and esophagus in thorax; and prostate in the male pelvis ( p < 0.05). Breast segmentation results showed low performance (DSC 0.66 ± 0.15, MSD 4.8 ± 1.93 mm, and HD95 22.2 ± 9.6 mm) compared to clinical reference, so the breast structure models are not recommended for clinical use. Abdominal structures (RayStation 2024A vs clinical) had DSC 0.95 ± 0.014; MSD 0.82 ± 0.32 mm; and HD95 5.4 ± 2.9 mm. The mean dose differences between DLS and clinical segmentations were 0.03 Gy for the head and neck, –0.92 Gy for the thorax, 0.27 Gy for the male pelvis, and 0.02 Gy for the abdominal sites, and the corresponding maximum dose differences were 10.96 Gy, 13.23 Gy, 3.39 Gy, and 6.31 Gy.

Conclusions

We described a procedure for practical quality assurance of auto‐segmentation tools for clinical use after periodic software upgrades. Regression testing of head and neck, thorax, and male pelvis sites showed consistent performance after the software upgrade and the DLS models for abdominal site were commissioned in this study for clinical use; while the DLS models for breast site were not recommended.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedDeep LearningSoftwareTomography, X-Ray ComputedImage Processing, Computer-AssistedQuality Assurance, Health CareHead and Neck NeoplasmsNeoplasmsHumansMaleRadiotherapy DosageOrgans at RiskRadiotherapy, Intensity-ModulatedFemaleRegression Analysis

Stichwörter der Autor:innen

auto‐segmentationcommercial softwaredeep learningquality assurance

Autor:innen und Institutionen

  • Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Department of Radiation Oncology, Baylor College of Medicine, Houston, Texas, USA.
  • Mayo Clinic, Rochester, Minnesota, USA.
  • Graduate School of Biomedical Sciences, The University of Texas MD Anderson Cancer Center UTHealth Houston, Houston, Texas, USA.
  • RaySearch Laboratories AB, Stockholm, Sweden.

ORCID-Profile: Roya Barati, Song Gao, Jared Ohrt, Jinzhong Yang

Förderung

  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Barati, R., Duan, J., Gao, S., Zhao, Y., Chen, X., Yu, C., Xu, Z., Khaleghibizaki, M., Lofman, F., Ohrt, J., Court, L., Balter, P., & Yang, J. (2026). Clinical evaluation and regression test of a commercial deep‐learning auto‐segmentation model. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70824

Vancouver

Barati R, Duan J, Gao S, Zhao Y, Chen X, Yu C, et al. Clinical evaluation and regression test of a commercial deep‐learning auto‐segmentation model. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70824

BibTeX
@article{Barati2026,
  author = {Barati, Roya and Duan, Jingwei and Gao, Song and Zhao, Yao and Chen, Xinru and Yu, Cenji and Xu, Zhan and Khaleghibizaki, Moghadaseh and Lofman, Fredrik and Ohrt, Jared and Court, Laurence and Balter, Peter and Yang, Jinzhong},
  title = {Clinical evaluation and regression test of a commercial deep‐learning auto‐segmentation model},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  doi = {10.1002/acm2.70824}
}
Kostenlos starten →