EUVIMEDObjevte EUVIMED
VergleichsstudieOpen access · CC BY 4.0

Comparison of liver stereotactic body radiotherapy plans based on free breathing and averaged CTs after trans‐arterial chemoembolization using lipiodol

Sei-Kwon Kang iD, Jai-Woong Yoon, Me Young Kim iD, Soah Park iD, Kwang-Ho Cheong iD, Taeryool Koo, Tae Jin Han

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70271 ↗

At a glance

Vergleichsstudie in Journal of Applied Clinical Medical Physics, 2025. Written by Sei-Kwon Kang and 6 co-authors. Institution: Department of Radiation Oncology, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul, South Korea. Major MEDLINE topics: Liver Neoplasms, Radiotherapy Planning, Computer-Assisted, Radiosurgery, Ethiodized Oil. 22 references. The full text is freely available (open access, CC BY 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Purpose

To identify which CT set is more suitable for predicting the four‐dimensional (4D) cumulative dose distribution in liver stereotactic body radiotherapy (SBRT) with lipiodol retention.

Methods

For 15 patients, who underwent liver SBRT after trans‐arterial chemoembolization (TACE), volumetric modulated arc therapy (VMAT) plans were retrospectively generated on free breathing (FB) and average intensity projection (AVG) CT sets using the x‐ray Voxel Monte Carlo (XVMC) algorithm. The three‐dimensional (3D) FB and AVG plans were compared with corresponding 4D plans, which were created by deformable registration using 10‐phase plans. For both internal target volume (ITV) and planning target volume (PTV), the volume covered by the prescription dose of 36 Gy (V36) and the dose covering 95% of the volume (D95) were evaluated. The relative (3D/4D) normal liver volume >19.2 Gy and rib volume 28.8 Gy were also compared for FB and AVG plans.

Results

The mean values of the relative electron densities inside the PTV for FB and AVG were slightly different (1.050 for FB vs. 1.039 for AVG). For both ITV and PTV, V36 and D95 showed no statistically significant difference between FB and AVG. Also, the relative rib volumes >28.8 Gy and the normal liver volumes >19.2 Gy were not statistically different between FB and AVG plans.

Conclusion

For liver SBRT with lipiodol retention, 3D plans based on FB and AVG images were virtually equivalent in producing the 4D cumulative doses under the accuracy of the XVMC algorithm.

Subjects

MeSH terms (MEDLINE)

Liver NeoplasmsRadiotherapy Planning, Computer-AssistedRadiosurgeryEthiodized OilChemoembolization, TherapeuticCarcinoma, HepatocellularHumansRadiotherapy DosageRetrospective StudiesRadiotherapy, Intensity-ModulatedRespirationMaleFemaleAlgorithmsOrgans at RiskAgedMiddle AgedMonte Carlo MethodFour-Dimensional Computed Tomography

Author keywords

4D cumulative doseaverage intensity projectionfree breathinglipiodolliver stereotactic body radiotherapy

Substances

Ethiodized Oil

Authors and institutions

  • Department of Radiation Oncology, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul, South Korea.
  • Department of Radiation Oncology, Dongtan Sacred Heart Hospital, Hwaseong, South Korea.
  • Department of Radiation Oncology, Chuncheon Sacred Heart Hospital, Hallym University College of Medicine, Chuncheon, Gangwon-do, South Korea.
  • Department of Radiation Oncology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, South Korea.
  • Department of Radiation Oncology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, South Korea.

ORCID profiles: Sei-Kwon Kang, Me Young Kim, Soah Park, Kwang-Ho Cheong

Cite

APA

Kang, S. K., Yoon, J. W., Kim, M. Y., Park, S., Cheong, K. H., Koo, T., & Han, T. J. (2025). Comparison of liver stereotactic body radiotherapy plans based on free breathing and averaged CTs after trans‐arterial chemoembolization using lipiodol. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70271

Vancouver

Kang SK, Yoon JW, Kim MY, Park S, Cheong KH, Koo T, et al. Comparison of liver stereotactic body radiotherapy plans based on free breathing and averaged CTs after trans‐arterial chemoembolization using lipiodol. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70271

BibTeX
@article{Kang2025,
  author = {Kang, Sei-Kwon and Yoon, Jai-Woong and Kim, Me Young and Park, Soah and Cheong, Kwang-Ho and Koo, Taeryool and Han, Tae Jin},
  title = {Comparison of liver stereotactic body radiotherapy plans based on free breathing and averaged CTs after trans‐arterial chemoembolization using lipiodol},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70271}
}
Start for free →