Comparison of liver stereotactic body radiotherapy plans based on free breathing and averaged CTs after trans‐arterial chemoembolization using lipiodol
Journal of Applied Clinical Medical Physics · 2025
DOI: 10.1002/acm2.70271 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Sei-Kwon Kang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul, South Korea. Hauptthemen laut MEDLINE: Liver Neoplasms, Radiotherapy Planning, Computer-Assisted, Radiosurgery, Ethiodized Oil. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To identify which CT set is more suitable for predicting the four‐dimensional (4D) cumulative dose distribution in liver stereotactic body radiotherapy (SBRT) with lipiodol retention.
Methods
For 15 patients, who underwent liver SBRT after trans‐arterial chemoembolization (TACE), volumetric modulated arc therapy (VMAT) plans were retrospectively generated on free breathing (FB) and average intensity projection (AVG) CT sets using the x‐ray Voxel Monte Carlo (XVMC) algorithm. The three‐dimensional (3D) FB and AVG plans were compared with corresponding 4D plans, which were created by deformable registration using 10‐phase plans. For both internal target volume (ITV) and planning target volume (PTV), the volume covered by the prescription dose of 36 Gy (V36) and the dose covering 95% of the volume (D95) were evaluated. The relative (3D/4D) normal liver volume >19.2 Gy and rib volume 28.8 Gy were also compared for FB and AVG plans.
Results
The mean values of the relative electron densities inside the PTV for FB and AVG were slightly different (1.050 for FB vs. 1.039 for AVG). For both ITV and PTV, V36 and D95 showed no statistically significant difference between FB and AVG. Also, the relative rib volumes >28.8 Gy and the normal liver volumes >19.2 Gy were not statistically different between FB and AVG plans.
Conclusion
For liver SBRT with lipiodol retention, 3D plans based on FB and AVG images were virtually equivalent in producing the 4D cumulative doses under the accuracy of the XVMC algorithm.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiation Oncology, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul, South Korea.
- Department of Radiation Oncology, Dongtan Sacred Heart Hospital, Hwaseong, South Korea.
- Department of Radiation Oncology, Chuncheon Sacred Heart Hospital, Hallym University College of Medicine, Chuncheon, Gangwon-do, South Korea.
- Department of Radiation Oncology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, South Korea.
- Department of Radiation Oncology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, South Korea.
ORCID-Profile: Sei-Kwon Kang, Me Young Kim, Soah Park, Kwang-Ho Cheong
Zitieren
APA
Kang, S. K., Yoon, J. W., Kim, M. Y., Park, S., Cheong, K. H., Koo, T., & Han, T. J. (2025). Comparison of liver stereotactic body radiotherapy plans based on free breathing and averaged CTs after trans‐arterial chemoembolization using lipiodol. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70271
Vancouver
Kang SK, Yoon JW, Kim MY, Park S, Cheong KH, Koo T, et al. Comparison of liver stereotactic body radiotherapy plans based on free breathing and averaged CTs after trans‐arterial chemoembolization using lipiodol. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70271
BibTeX
@article{Kang2025,
author = {Kang, Sei-Kwon and Yoon, Jai-Woong and Kim, Me Young and Park, Soah and Cheong, Kwang-Ho and Koo, Taeryool and Han, Tae Jin},
title = {Comparison of liver stereotactic body radiotherapy plans based on free breathing and averaged CTs after trans‐arterial chemoembolization using lipiodol},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.70271}
}
EUVIMED