EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Implementation of intelligent All‐in‐one technology in rectal cancer radiotherapy: A retrospective study on automation efficiency and safety

Haoyang Zhai, Jiazhou Wang iD, Weigang Hu

Journal of Applied Clinical Medical Physics · 2025-09 · 26 (9)

DOI: 10.1002/acm2.70236 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 10.09.2025. Verfasst von Haoyang Zhai und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Department of Oncology, Shanghai Clinical Research Center for Radiation On…. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Rectal Neoplasms, Organs at Risk, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Shanghai Committee of Science and Technology Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aims to assess percentage of automated AIO plans that met clinical treatment standards of radiotherapy plans generated by the fully automated All‐in‐one (AIO) process.

Methods

The study involved 117 rectal cancer patients who underwent AIO treatment. Fully automated regions of interest (ROI) and treatment plans were developed without manual intervention, comparing them to manually generated plans used in clinical practice. Geometric and dosimetric metrics were collected from both automated and manual plans. The relationship between the geometric and dosimetric metrics of the planning target volume (PTV) was evaluated using Spearman correlation analysis. The interquartile range (IQR) method was applied to determine the percentage of automated plans meeting clinical requirements. Additionally, dosimetric metrics for organs at risk (OAR) were compared between automated and manual plans using paired t ‐tests. The reasons for dose discrepancies were examined based on target volume.

Results

Spearman correlation analysis showed a moderate correlation between geometric metrics and the conformity index (△CI) in dosimetric metrics. The correlation coefficients were as follows: Hausdorff distance (HD, |ρ| = 0.458, p < 0.01), Mean deviation area (MDA, |ρ| = 0.565, p < 0.01), Dice similarity coefficient (DSC, |ρ| = 0.631, p < 0.01), and Jaccard index (JI, |ρ| = 0.632, p < 0.01). Statistical analysis revealed that the mean doses to the bladder and bilateral femoral heads were significantly lower in automated plans compared to manual ones ( p < 0.01). This difference is likely due to variations in ROI delineation between automated and manual methods. The IQR method showed that 81.2% of automated AIO plans met clinical requirements without manual intervention.

Conclusion

In routine clinical practice, approximately 81.2% of automated AIO plans met clinical requirements without requiring manual intervention.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedRectal NeoplasmsOrgans at RiskRadiotherapy, Intensity-ModulatedHumansRadiotherapy DosageRetrospective StudiesAutomationAlgorithms

Stichwörter der Autor:innen

All‐in‐oneautomated planningclinical practicedosimetric metric

Autor:innen und Institutionen

  • Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Department of Oncology, Shanghai Clinical Research Center for Radiation Oncology, Shanghai Key Laboratory of Radiation Oncology, Shanghai Medica…

ORCID-Profile: Jiazhou Wang

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • Shanghai Committee of Science and Technology Fund

Zitieren

APA

Zhai, H., Wang, J., & Hu, W. (2025). Implementation of intelligent All‐in‐one technology in rectal cancer radiotherapy: A retrospective study on automation efficiency and safety. Journal of Applied Clinical Medical Physics, 26(9). https://doi.org/10.1002/acm2.70236

Vancouver

Zhai H, Wang J, Hu W. Implementation of intelligent All‐in‐one technology in rectal cancer radiotherapy: A retrospective study on automation efficiency and safety. Journal of Applied Clinical Medical Physics. 2025;26(9). doi:10.1002/acm2.70236

BibTeX
@article{Zhai2025,
  author = {Zhai, Haoyang and Wang, Jiazhou and Hu, Weigang},
  title = {Implementation of intelligent All‐in‐one technology in rectal cancer radiotherapy: A retrospective study on automation efficiency and safety},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  volume = {26},
  number = {9},
  doi = {10.1002/acm2.70236}
}
Kostenlos starten →