EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY 4.0

Evaluation of the availability of single‐position treatment with a rotating gantry and the validity of deformable image registration dose assessment for pancreatic cancer carbon‐ion radiotherapy

Yuya Miyasaka, Shohei Kawashiro, Sung Hyun Lee, Hikaru Souda iD, Mayumi Ichikawa, Hongbo Chai, Miyu Ishizawa, Takuya Ono, Hiraku Sato, Takeo Iwai

Journal of Applied Clinical Medical Physics · 2024

DOI: 10.1002/acm2.14330 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Yuya Miyasaka und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan. Hauptthemen laut MEDLINE: Pancreatic Neoplasms, Radiotherapy Planning, Computer-Assisted, Radiotherapy Dosage, Heavy Ion Radiotherapy. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study aimed to evaluate the clinical acceptability of rotational gantry‐based single‐position carbon‐ion radiotherapy (CIRT) to reduce the gastrointestinal (GI) dose in pancreatic cancer. We also evaluated the usefulness of the deformable image registration (DIR)‐based dosimetry method for CIRT. Material and methods Fifteen patients with pancreatic cancer were analyzed. The treatment plans were developed for four beam angles in the supine (SP plan) and prone (PR plan) positions. In the case of using multiple positions, the treatment plan was created with two angles for each of the supine and prone position (SP + PR plan). Dose evaluation for multiple positions was performed in two ways: by directly adding the values of the DVH parameters for each position treatment plan (DVH sum), and by calculating the DVH parameters from the accumulative dose distribution created using DIR (DIR sum). The D 2cc and D 6cc of the stomach and duodenum were recorded for each treatment plan and dosimetry method and compared.

Results

There were no significant differences among any of the treatment planning and dosimetry methods ( p > 0.05). The DVH parameters for the stomach and duodenum were higher in the PR plan and SP plan, respectively, and DVH sum tended to be between the SP and PR plans. DVH sum and DIR sum, DVH sum tended to be higher for D 2cc and DIR sum tended to be higher for D 6cc .

Conclusion

There were no significant differences in the GI dose, which suggests that treatment with a simple workflow performed in one position should be clinically acceptable. In CIRT, DIR‐based dosimetry should be carefully considered because of the potential for increased uncertainty due to the steep dose distributions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pancreatic NeoplasmsRadiotherapy Planning, Computer-AssistedRadiotherapy DosageHeavy Ion RadiotherapyOrgans at RiskRadiotherapy, Intensity-ModulatedHumansPatient PositioningMaleFemaleImage Processing, Computer-AssistedAgedMiddle AgedPrognosis

Stichwörter der Autor:innen

carbon‐ion therapydeformable image registrationdose evaluationpancreas cancertreatment planning

Autor:innen und Institutionen

  • Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
  • Department of Radiation Oncology, Kanagawa Cancer Center, Yokohama, Japan.
  • Department of Radiology, Yamagata University Faculty of Medicine, Yamagata, Japan.

ORCID-Profile: Hikaru Souda

Zitieren

APA

Miyasaka, Y., Kawashiro, S., Lee, S. H., Souda, H., Ichikawa, M., Chai, H., Ishizawa, M., Ono, T., Sato, H., & Iwai, T. (2024). Evaluation of the availability of single‐position treatment with a rotating gantry and the validity of deformable image registration dose assessment for pancreatic cancer carbon‐ion radiotherapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14330

Vancouver

Miyasaka Y, Kawashiro S, Lee SH, Souda H, Ichikawa M, Chai H, et al. Evaluation of the availability of single‐position treatment with a rotating gantry and the validity of deformable image registration dose assessment for pancreatic cancer carbon‐ion radiotherapy. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14330

BibTeX
@article{Miyasaka2024,
  author = {Miyasaka, Yuya and Kawashiro, Shohei and Lee, Sung Hyun and Souda, Hikaru and Ichikawa, Mayumi and Chai, Hongbo and Ishizawa, Miyu and Ono, Takuya and Sato, Hiraku and Iwai, Takeo},
  title = {Evaluation of the availability of single‐position treatment with a rotating gantry and the validity of deformable image registration dose assessment for pancreatic cancer carbon‐ion radiotherapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14330}
}