Routine machine quality assurance tests for a self‐shielded gyroscopic radiosurgery system

Yongsook C Lee, Ranjini Tolakanahalli, D Jay Wieczorek, Minesh P Mehta, Michael W McDermott, Rupesh Kotecha, Alonso N Gutierrez

Journal of Applied Clinical Medical Physics · 2025-04 · 26 (4)

DOI: 10.1002/acm2.14589 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 14.12.2024. Verfasst von Yongsook C Lee und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, Florida, USA. Hauptthemen laut MEDLINE: Radiosurgery, Quality Assurance, Health Care, Phantoms, Imaging, Radiotherapy Planning, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This report describes routine machine quality assurance (QA) (daily, monthly, and annual QA) tests for the Zap‐X ® Gyroscopic Radiosurgery ® platform.

Methods

Following the recommendations of the American Association of Physicists in Medicine Task Group (AAPM TG)‐142 and Medical Physics Practice guideline (MPPG) 8.b, routine machine QA tests for the Zap‐X system were implemented. The implementation included (1) daily, monthly, and annual QA tests encompassing dosimetry, mechanical, safety and imaging tests, (2) QA methods of each test specific to the Zap‐X, (3) a tolerance value for each test, and (4) necessary QA equipment.

Results

Baseline values and key results of daily, monthly, and annual QA tests are presented in this report. This report also discusses QA tests not adopted from TG 142 or MPPG 8.b (e.g., distance indicator) due to unique features of the Zap‐X system as well as additional QA tests added from the vendor's recommendations (e.g., self‐check) and from TG‐135 recommendations (e.g., monthly end‐to‐end testing) because of similarities between Zap‐X and CyberKnife systems.

Conclusions

The comprehensive information on routine machine QA tests presented in this report will assist Zap‐X teams in other Neurosurgery centers or Radiation Oncology clinics in establishing and maintaining their QA programs until AAPM endorsed guidelines become available.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiosurgeryQuality Assurance, Health CarePhantoms, ImagingRadiotherapy Planning, Computer-AssistedRadiation ProtectionHumansRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiometryQuality Control

Stichwörter der Autor:innen

Zap‐Xgyroscopicmachine quality assuranceradiosurgeryself‐shielded

Autor:innen und Institutionen

  • Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, Florida, USA.
  • Department of Radiation Oncology, Herbert Wertheim College of Medicine, Florida International University, Miami, Florida, USA.
  • Department of Translational Medicine, Herbert Wertheim College of Medicine, Florida International University, Miami, Florida, USA.
  • Department of Neurosurgery, Miami Neuroscience Institute, Baptist Health South Florida, Miami, Florida, USA.

Zitieren

APA

Lee, Y. C., Tolakanahalli, R., Wieczorek, D. J., Mehta, M. P., McDermott, M. W., Kotecha, R., & Gutierrez, A. N. (2025). Routine machine quality assurance tests for a self‐shielded gyroscopic radiosurgery system. Journal of Applied Clinical Medical Physics, 26(4). https://doi.org/10.1002/acm2.14589

Vancouver

Lee YC, Tolakanahalli R, Wieczorek DJ, Mehta MP, McDermott MW, Kotecha R, et al. Routine machine quality assurance tests for a self‐shielded gyroscopic radiosurgery system. Journal of Applied Clinical Medical Physics. 2025;26(4). doi:10.1002/acm2.14589

BibTeX
@article{Lee2025,
  author = {Lee, Yongsook C and Tolakanahalli, Ranjini and Wieczorek, D Jay and Mehta, Minesh P and McDermott, Michael W and Kotecha, Rupesh and Gutierrez, Alonso N},
  title = {Routine machine quality assurance tests for a self‐shielded gyroscopic radiosurgery system},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  volume = {26},
  number = {4},
  doi = {10.1002/acm2.14589}
}
Kostenlos starten →