EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Characterization of novel 3D‐printed metal shielding for brachytherapy applicators

K Maiti McGrath, Krista Chytyk-Praznik iD, Amanda Cherpak

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.14541 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von K Maiti McGrath und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada. Hauptthemen laut MEDLINE: Brachytherapy, Radiotherapy Dosage, Printing, Three-Dimensional, Monte Carlo Method. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To characterize 3D‐printed stainless steel metal samples in the presence of an Iridium‐192 source for organ‐at‐risk sparing in gynecologic brachytherapy.

Methods

Samples of 3D‐printed stainless steel (5.5 × 5.5 cm 2 , thickness range 1–5 mm) were embedded in a solid water phantom at varying distances from source catheters. An Ir‐192 brachytherapy source was passed through the phantom and the dose was measured using EBT3 Gafchromic film. The film was initially positioned in the sagittal plane 2 cm away from the catheters, with the metal directly below and then 1 cm from the film. A uniform dose was delivered at the film plane. A second setup measured a depth dose curve in solid water with film in the transverse plane directly above the metal samples. This setup was recreated using Monte Carlo simulations (EGSnrc egs_brachy). Validation between methods was performed with unshielded (solid water only) measurements.

Results

The planar dose passing through the metal samples (thickness 1–5 mm) at the midpoint between the film and catheters, decreased compared to solid water by 7.4% ± 6.9% to 26.5% ± 5.5%. Dose enhancement on the order of 5% was noted when metal was directly adjacent to the film. The average decrease in depth dose from a single dwell position ranged from 10.0% ± 5.9% (1 mm) to 21.1% ± 5.3% (5 mm) as measured with film, and from 3.8% ± 0.9% (1 mm) to 16.3% ± 0.9% (5 mm) using MC simulation. The average depth dose values were measured using a line width of 2.5 mm for film, and 3 mm for MC simulation, and the measurements generally agree within standard error.

Conclusions

The 3D‐printed metal samples show potential for personalized applicators. Maximum dose reduction of 26.5% ± 5.5% compared to solid water was measured at 2 cm from the source using the 5 mm sample. An outer layer of solid water could potentially be used to reduce dose enhancement due to increased scatter near the metal.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrachytherapyRadiotherapy DosagePrinting, Three-DimensionalMonte Carlo MethodPhantoms, ImagingIridium RadioisotopesRadiotherapy Planning, Computer-AssistedHumansFemaleMetalsRadiation ProtectionOrgans at Risk

Stichwörter der Autor:innen

3D printed applicatorsgynecological brachytherapyshielded applicators

Substanzen

Iridium RadioisotopesIridium-192Metals

Autor:innen und Institutionen

  • Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada.
  • Department of Radiation Oncology, Dalhousie University, Halifax, Canada.
  • QE2 Cancer Centre, Nova Scotia Health, Halifax, Canada.

ORCID-Profile: Krista Chytyk-Praznik

Zitieren

APA

McGrath, K. M., Chytyk-Praznik, K., & Cherpak, A. (2025). Characterization of novel 3D‐printed metal shielding for brachytherapy applicators. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14541

Vancouver

McGrath KM, Chytyk-Praznik K, Cherpak A. Characterization of novel 3D‐printed metal shielding for brachytherapy applicators. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.14541

BibTeX
@article{McGrath2025,
  author = {McGrath, K Maiti and Chytyk-Praznik, Krista and Cherpak, Amanda},
  title = {Characterization of novel 3D‐printed metal shielding for brachytherapy applicators},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.14541}
}
Kostenlos starten →