Time structures of proton pencil beam scanning delivery on a microsecond scale measured with a pixelated semiconductor detector Timepix3
Journal of Applied Clinical Medical Physics · 2024
DOI: 10.1002/acm2.14486 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Jiajian Shen und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA. Hauptthemen laut MEDLINE: Proton Therapy, Semiconductors, Radiotherapy Dosage, Particle Accelerators. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
The time structures of proton spot delivery in proton pencil beam scanning (PBS) radiation therapy are essential in many clinical applications. This study aims to characterize the time structures of proton PBS delivered by both synchrotron and synchrocyclotron accelerators using a non‐invasive technique based on scattered particle tracking.
Methods
A pixelated semiconductor detector, AdvaPIX‐Timepix3, with a temporal resolution of 1.56 ns, was employed to measure time of arrival of secondary particles generated by a proton beam. The detector was placed laterally to the high‐flux area of the beam in order to allow for single particle detection and not interfere with the treatment. The detector recorded counts of radiation events, their deposited energy and the timestamp associated with the single events. Individual recorded events and their temporal characteristics were used to analyze beam time structures, including energy layer switch time, magnet switch time, spot switch time, and the scanning speeds in the x and y directions. All the measurements were repeated 30 times on three dates, reducing statistical uncertainty.
Results
The uncertainty of the measured energy layer switch times, magnet switch time, and the spot switch time were all within 1% of average values. The scanning speeds uncertainties were within 1.5% and are more precise than previously reported results. The measurements also revealed continuous sub‐milliseconds proton spills at a low dose rate for the synchrotron accelerator and radiofrequency pulses at 7 µs and 1 ms repetition time for the synchrocyclotron accelerator.
Conclusion
The AdvaPIX‐Timepix3 detector can be used to directly measure and monitor time structures on microseconds scale of the PBS proton beam delivery. This method yielded results with high precision and is completely independent of the machine log files.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.
- Department of Radiation Oncology, Corewell Health Beaumont University Hospital, Royal Oak, Michigan, USA.
- Department of Radiation Oncology, Stanford University, Palo Alto, California, USA.
- Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida, USA.
- ADVACAM, Prague, Czech Republic.
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
ORCID-Profile: Jiajian Shen, Xiaoying Liang, Wei Liu
Zitieren
APA
Shen, J., Ding, X., Charyyev, S., Liang, X., Oancea, C., Wang, P., Rule, W. G., Liu, W., Bues, M., & Lin, L. (2024). Time structures of proton pencil beam scanning delivery on a microsecond scale measured with a pixelated semiconductor detector Timepix3. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14486
Vancouver
Shen J, Ding X, Charyyev S, Liang X, Oancea C, Wang P, et al. Time structures of proton pencil beam scanning delivery on a microsecond scale measured with a pixelated semiconductor detector Timepix3. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14486
BibTeX
@article{Shen2024,
author = {Shen, Jiajian and Ding, Xuanfeng and Charyyev, Serdar and Liang, Xiaoying and Oancea, Cristina and Wang, Peilong and Rule, William G and Liu, Wei and Bues, Martin and Lin, Liyong},
title = {Time structures of proton pencil beam scanning delivery on a microsecond scale measured with a pixelated semiconductor detector Timepix3},
journal = {Journal of Applied Clinical Medical Physics},
year = {2024},
doi = {10.1002/acm2.14486}
}
EUVIMED