EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparative evaluation of image‐guided radiation therapy (IGRT)‐based dose calculation accuracy using cone‐beam, megavoltage, and kilovoltage CT modalities

Sirawit Saobai, Anirut Watcharawipha, Somsak Wanwilairat, Warit Thongsuk iD, Wannapha Nobnop iD

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70379 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Sirawit Saobai und 4 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics Program, Department of Radiology, Faculty of Medicine, ChiangMai University, Chiang Mai, Thailand. Hauptthemen laut MEDLINE: Radiotherapy, Image-Guided, Radiotherapy Planning, Computer-Assisted, Phantoms, Imaging, Cone-Beam Computed Tomography. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study evaluates the dosimetric accuracy of three image‐guided radiotherapy (IGRT) imaging modalities, cone‐beam computed tomography (CBCT), megavoltage computed tomography (MVCT), and image‐guided kilovoltage computed tomography (IG‐kVCT), using modality‐specific HU‐to‐density (HU‐D) calibrations. Dose calculations from IGRT images were compared to computed tomography simulation (CT‐sim) references in phantoms and validated against measurements from head and neck and prostate patient plans to assess the feasibility of each modality for precise dose calculation in adaptive radiotherapy (ART).

Methods

Two phantoms, the Tomo phantom HE and CIRS Thorax phantom, were used for HU‐to‐density (HU‐D) calibration. IGRT images were acquired using Elekta Synergy XVI (CBCT) and Radixact X9 (MVCT and IG‐kVCT), and calibration curves were generated for each modality. Dose distributions calculated from IGRT images were then compared with those from CT‐sim in phantom studies. For measurement‐based evaluation, 10 patient plans (head and neck and prostate cases) were delivered to a phantom and measured using the ArcCHECK system, and recalculated doses on CT‐sim and IGRT images were compared to the measured doses. Gamma analysis was performed to assess dosimetric accuracy.

Results

IG‐kVCT showed the closest agreement with CT‐sim, achieving gamma passing rates (GPR) of 99.8% ± 0.3% for 3%/3 mm and 98.5% ± 0.7% for 3%/2 mm criteria, with dose differences below 1%. CBCT and MVCT demonstrated slightly lower accuracy, with GPRs of 97.2% ± 1.1% and 96.5% ± 1.3% for 3%/3 mm, respectively, and dose differences up to 2%. Similar trends were observed when compared to measured doses. All IGRT modalities showed clinically acceptable agreement, and no statistically significant differences were found between CT‐sim and any IGRT modality.

Conclusion

All three IGRT modalities demonstrated clinically acceptable accuracy for adaptive dose calculation with modality‐specific HU‐D calibration curves.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedPhantoms, ImagingCone-Beam Computed TomographyHead and Neck NeoplasmsProstatic NeoplasmsTomography, X-Ray ComputedHumansRadiotherapy DosageMaleRadiotherapy, Intensity-ModulatedCalibrationImage Processing, Computer-Assisted

Stichwörter der Autor:innen

Hounsfield unit‐to‐density calibration (HU‐D)IG‐kVCTMVCTcone‐beam CT (CBCT)dose re‐calculationimage‐guided radiation therapy (IGRT)

Autor:innen und Institutionen

  • Medical Physics Program, Department of Radiology, Faculty of Medicine, ChiangMai University, Chiang Mai, Thailand.
  • Division of Radiation Oncology, Department of Radiology, Faculty of Medicine, ChiangMai University, Chiang Mai, Thailand.

ORCID-Profile: Warit Thongsuk, Wannapha Nobnop

Zitieren

APA

Saobai, S., Watcharawipha, A., Wanwilairat, S., Thongsuk, W., & Nobnop, W. (2025). Comparative evaluation of image‐guided radiation therapy (IGRT)‐based dose calculation accuracy using cone‐beam, megavoltage, and kilovoltage CT modalities. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70379

Vancouver

Saobai S, Watcharawipha A, Wanwilairat S, Thongsuk W, Nobnop W. Comparative evaluation of image‐guided radiation therapy (IGRT)‐based dose calculation accuracy using cone‐beam, megavoltage, and kilovoltage CT modalities. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70379

BibTeX
@article{Saobai2025,
  author = {Saobai, Sirawit and Watcharawipha, Anirut and Wanwilairat, Somsak and Thongsuk, Warit and Nobnop, Wannapha},
  title = {Comparative evaluation of image‐guided radiation therapy (IGRT)‐based dose calculation accuracy using cone‐beam, megavoltage, and kilovoltage CT modalities},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70379}
}
Kostenlos starten →