EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY 4.0

Contour and dosimetric evaluation of an in-room mobile CBCT scanner for cylinder based brachytherapy

Nilanjan Haldar, Keita Okazaki, LaToya McLean, Firas Mourtada, Reza Taleei, Jun Li, Joseph Caster, Pramila Rani Anne, Yevgeniy Vinogradskiy, Wookjin Choi, Yingxuan Chen

Brachytherapy · 2026

DOI: 10.1016/j.brachy.2026.05.007 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Brachytherapy, 2026. Verfasst von Nilanjan Haldar und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA. Hauptthemen laut MEDLINE: Brachytherapy, Cone-Beam Computed Tomography, Radiotherapy Planning, Computer-Assisted. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Elekta AB, Thomas Jefferson University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: In-room cone-beam CT (CBCT) is an emerging imaging solution for brachytherapy. This study evaluates organ-at-risk (OAR) contour and dosimetric differences between CT- and CBCT-based treatment plans for cylinder-based brachytherapy. MATERIALS AND METHODS: Ten patients who received high-dose-rate (HDR) cylinder-based brachytherapy were retrospectively analyzed. Standard pelvic CT images were used for treatment planning, and in-room CBCT images were acquired prior to the treatment to verify cylinder placement. The CT-based plans were replanned on their corresponding CBCT images. OARs were independently contoured on both CT and CBCT and compared using Dice similarity coefficient (DSC), and Hausdorff distance (HD). Dosimetrically, D₂cc were compared between CT and CBCT. RESULTS: Among the ten patients, CBCT provided reliable images for HDR cylinder treatment planning in terms of applicator digitalization and OAR delineation. Considerable variabilities between CT and CBCT for OARs were observed. Median DSC values were 0.73, 0.78, 0.74, and 0.48 and median HD values were 15.5 mm, 12.2 mm, 16.0 mm, and 22.5 mm for the bladder, rectum, small bowel, and sigmoid, respectively. Median values of D₂cc differences between the CT-based plans and the CBCT-based plans were 3.4 cGy, 25.1 cGy, 26.2 cGy, and 58.3 cGy for the bladder, rectum, small bowel, and sigmoid, respectively. CONCLUSION: In-room mobile CBCT provides a practical and efficient solution for vaginal cylinder HDR brachytherapy. The image quality was sufficient for accurate delineation of the applicator and OARs, helping streamline the workflow. Although inter-fractional variations in OAR position and volume were observed, these changes remained within clinically acceptable limits.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrachytherapyCone-Beam Computed TomographyRadiotherapy Planning, Computer-AssistedHumansFemaleRadiotherapy DosageRetrospective StudiesRadiometryRadiotherapy, Image-GuidedMale

Stichwörter der Autor:innen

CTHDR brachytherapyIn-room CBCT

Autor:innen und Institutionen

  • Department of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA.
  • Department of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA. Electronic address: Yingxuan.chen@jefferson.edu.

Förderung

  • Elekta AB
  • Thomas Jefferson University

Zitieren

APA

Haldar, N., Okazaki, K., McLean, L., Mourtada, F., Taleei, R., Li, J., Caster, J., Anne, P. R., Vinogradskiy, Y., Choi, W., & Chen, Y. (2026). Contour and dosimetric evaluation of an in-room mobile CBCT scanner for cylinder based brachytherapy. Brachytherapy. https://doi.org/10.1016/j.brachy.2026.05.007

Vancouver

Haldar N, Okazaki K, McLean L, Mourtada F, Taleei R, Li J, et al. Contour and dosimetric evaluation of an in-room mobile CBCT scanner for cylinder based brachytherapy. Brachytherapy. 2026. doi:10.1016/j.brachy.2026.05.007

BibTeX
@article{Haldar2026,
  author = {Haldar, Nilanjan and Okazaki, Keita and McLean, LaToya and Mourtada, Firas and Taleei, Reza and Li, Jun and Caster, Joseph and Anne, Pramila Rani and Vinogradskiy, Yevgeniy and Choi, Wookjin and Chen, Yingxuan},
  title = {Contour and dosimetric evaluation of an in-room mobile CBCT scanner for cylinder based brachytherapy},
  journal = {Brachytherapy},
  year = {2026},
  doi = {10.1016/j.brachy.2026.05.007}
}
Kostenlos starten →