EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Utilizing collimated aperture with proton pencil beam scanning (PBS) for stereotactic radiotherapy

Chen-Yu Chou, Tsung-Shiau Tsai, Hsiao-Chieh Huang, Chun-Chieh Wang, Shen-Hao Lee, Shih-Ming Hsu

Journal of Applied Clinical Medical Physics · 2024

DOI: 10.1002/acm2.14362 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Chen-Yu Chou und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan (R.O.C). Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiosurgery, Radiotherapy Dosage, Proton Therapy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Proton stereotactic radiosurgery (PSRS) has emerged as an innovative proton therapy modality aimed at achieving precise dose delivery with minimal impact on healthy tissues. This study explores the dosimetric outcomes of PSRS in comparison to traditional intensity‐modulated proton therapy (IMPT) by focusing on cases with small target volumes. A custom‐made aperture system designed for proton therapy, specifically tailored to small target volumes, was developed and implemented for this investigation.

Methods

A prerequisite mechanical validation through an isocentricity test precedes dosimetric assessments, ensuring the seamless integration of mechanical and dosimetry analyses. Five patients were enrolled in the study, including two with choroid melanoma and three with arteriovenous malformations (AVM). Two treatment plans were meticulously executed for each patient, one utilizing a collimated aperture and the other without. Both plans were subjected to robust optimization, maintaining identical beam arrangements and consistent optimization parameters to account for setup errors of 2 mm and range uncertainties of 3.5%. Plan evaluation metrics encompassing the Heterogeneity Index (HI), Paddick Conformity Index (CI Paddick ), Gradient Index (GI), and the R50% index to evaluate alterations in low‐dose volume distribution.

Results

The comparative analysis between PSRS and traditional PBS treatment revealed no significant differences in plan outcomes, with both modalities demonstrating comparable target coverage. However, collimated apertures resulted in discernible improvements in dose conformity, dose fall‐off, and reduced low‐dose volume.

Conclusions

This study underscores the advantageous impact of the aperture system on proton therapy, particularly in cases involving small target volumes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedRadiosurgeryRadiotherapy DosageProton TherapyRadiotherapy, Intensity-ModulatedOrgans at RiskHumansMelanoma

Stichwörter der Autor:innen

IMPTPBSPSRSapertureradiosurgery

Autor:innen und Institutionen

  • Department of Radiation Oncology, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan (R.O.C).
  • Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei City, Taiwan (R.O.C).

Zitieren

APA

Chou, C. Y., Tsai, T. S., Huang, H. C., Wang, C. C., Lee, S. H., & Hsu, S. M. (2024). Utilizing collimated aperture with proton pencil beam scanning (PBS) for stereotactic radiotherapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14362

Vancouver

Chou CY, Tsai TS, Huang HC, Wang CC, Lee SH, Hsu SM. Utilizing collimated aperture with proton pencil beam scanning (PBS) for stereotactic radiotherapy. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14362

BibTeX
@article{Chou2024,
  author = {Chou, Chen-Yu and Tsai, Tsung-Shiau and Huang, Hsiao-Chieh and Wang, Chun-Chieh and Lee, Shen-Hao and Hsu, Shih-Ming},
  title = {Utilizing collimated aperture with proton pencil beam scanning (PBS) for stereotactic radiotherapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14362}
}
Kostenlos starten →