EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimization of collimator angle combined island blocking with parked gap achieves superior normal tissue sparing in SBRT planning of multiple liver lesions

Maidina Abuduxiku, Xiaoqiang Chen, Shu Zhang, Jiangping Yang, Wenjun Liao, Jianghong Xiao iD

Journal of Applied Clinical Medical Physics · 2024-06 · 25 (6)

DOI: 10.1002/acm2.14267 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 23.01.2024. Verfasst von Maidina Abuduxiku und 5 weiteren Autor:innen. Beteiligte Einrichtung: Radiotherapy Physics & Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Liver Neoplasms, Radiotherapy Dosage, Radiosurgery. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Sichuan Science and Technology Program, China, New Technology Program, West China Hospital, Sichuan University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To propose an efficient collimator angle optimization method by combining island blocking (IB) and parked gap (PG) problem to reduce the radiotherapy dose for normal tissue. The reduction will be done with single‐isocenter multi‐lesion volumetric modulated arc therapy (VMAT) for the stereotactic body radiation therapy (SBRT) of liver cancer.

Methods

A novel collimator angle optimization algorithm was developed based on the two‐dimensional projection of targets on a beam's eye view (BEV) plane as a function of gantry and collimator angle. This optimization algorithm minimized the sum of the combined IB and PG (IB & PG) areas from all gantry angles for each arc. For comparison, two SBRT plans were respectively generated for each of the 20 retrospective liver cancer cases with multiple lesions. One plan was optimized using the IB & PG algorithm, and the other plan was optimized with a previously reported optimization algorithm that only considered the IB area. Plans were then evaluated and compared using typical dosimetric metrics.

Results

With the comparable target coverage, IB & PG plans had significantly lower D 500cc , D 700cc , mean dose ( D mean ), and V 15 of normal liver tissues when compared to IB plans. The median percent reductions were 3.32% to 5.36%. The D 1cc , D 5cc , and D mean for duodenum and small intestine in IB & PG plans were significantly reduced in a range from 7.60% up to 16.03%. Similarly, the median integral dose was reduced by 3.73%. Furthermore, the percentage of normal liver D mean sparing when IB & PG plans compared to IB plans, was found to be positively correlated ( ρ = 0.669, P = 0.001) with the inter‐target distance.

Conclusion

The proposed IB & PG algorithm has been demonstrated to outperform the IB algorithm in almost all normal tissue sparing, and the magnitude of liver sparing was positively correlated with inter‐target distance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedLiver NeoplasmsRadiotherapy DosageRadiosurgeryRadiotherapy, Intensity-ModulatedOrgans at RiskAlgorithmsHumansRetrospective StudiesPrognosisOrgan Sparing Treatments

Stichwörter der Autor:innen

collimator angle optimizationisland blockingmultiple lesionsparked gapstereotactic body radiation therapy

Autor:innen und Institutionen

  • Radiotherapy Physics & Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
  • Head and Neck Oncology Department, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
  • Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
  • Department of Radiation Oncology, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, China.

ORCID-Profile: Jianghong Xiao

Förderung

  • National Natural Science Foundation of China
  • Sichuan Science and Technology Program, China
  • New Technology Program, West China Hospital, Sichuan University

Zitieren

APA

Abuduxiku, M., Chen, X., Zhang, S., Yang, J., Liao, W., & Xiao, J. (2024). Optimization of collimator angle combined island blocking with parked gap achieves superior normal tissue sparing in SBRT planning of multiple liver lesions. Journal of Applied Clinical Medical Physics, 25(6). https://doi.org/10.1002/acm2.14267

Vancouver

Abuduxiku M, Chen X, Zhang S, Yang J, Liao W, Xiao J. Optimization of collimator angle combined island blocking with parked gap achieves superior normal tissue sparing in SBRT planning of multiple liver lesions. Journal of Applied Clinical Medical Physics. 2024;25(6). doi:10.1002/acm2.14267

BibTeX
@article{Abuduxiku2024,
  author = {Abuduxiku, Maidina and Chen, Xiaoqiang and Zhang, Shu and Yang, Jiangping and Liao, Wenjun and Xiao, Jianghong},
  title = {Optimization of collimator angle combined island blocking with parked gap achieves superior normal tissue sparing in SBRT planning of multiple liver lesions},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  volume = {25},
  number = {6},
  doi = {10.1002/acm2.14267}
}
Kostenlos starten →