Model‐based quantitative photoacoustic tomography with directional total variation
Journal of Biophotonics · 2024
DOI: 10.1002/jbio.202400128 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biophotonics, 2024. Verfasst von Jiaming Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Shunde Hospital, Southern Medical University (The First People's Hospital of Shunde), Foshan, China. Hauptthemen laut MEDLINE: Photoacoustic Techniques, Phantoms, Imaging, Tomography, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: China Postdoctoral Science Foundation, Guangdong Basic and Applied Basic Research Foundation, National Natural Science Foundation of China.
Abstract (Originalsprache)
In photoacoustic tomography (PAT), acoustic inversion aims to recover the spatial distribution of light energy deposition within the imaging object from the signals captured by detectors. To achieve quantitative imaging, optical inversion is further employed to derive absorption coefficient (AC) images. However, limitations such as restricted detection angles and inherent noise lead to substantial artifacts and degradation in the quality of PAT images, consequently affecting the accuracy of optical inversion results. In this study, we propose a directional total variation constrained optical inversion model to reconstruct the AC image. By incorporating anatomy prior information into the optical inversion process, our method can effectively suppress artifacts in AC images while maintaining structural integrity. Simulation, phantom, and in vivo experimental results demonstrate that our method significantly improves the reconstructed AC image quality. Our method provides a reliable foundation for achieving high‐quality quantitative PAT imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Shunde Hospital, Southern Medical University (The First People's Hospital of Shunde), Foshan, China.
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, China.
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong, China.
- Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, Guangdong, China.
ORCID-Profile: Shuangyang Zhang
Förderung
- China Postdoctoral Science Foundation
- Guangdong Basic and Applied Basic Research Foundation
- National Natural Science Foundation of China
- Basic and Applied Basic Research Foundation of Guangdong Province
Zitieren
APA
Liu, J., Qi, L., Feng, Y., Hu, Q., & Zhang, S. (2024). Model‐based quantitative photoacoustic tomography with directional total variation. Journal of Biophotonics. https://doi.org/10.1002/jbio.202400128
Vancouver
Liu J, Qi L, Feng Y, Hu Q, Zhang S. Model‐based quantitative photoacoustic tomography with directional total variation. Journal of Biophotonics. 2024. doi:10.1002/jbio.202400128
BibTeX
@article{Liu2024,
author = {Liu, Jiaming and Qi, Li and Feng, Yanqiu and Hu, Qiugen and Zhang, Shuangyang},
title = {Model‐based quantitative photoacoustic tomography with directional total variation},
journal = {Journal of Biophotonics},
year = {2024},
doi = {10.1002/jbio.202400128}
}
EUVIMED