EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dosimetric impact of MLC positional errors on dose distribution in IMRT

Hiromi Enomoto iD, Yukio Fujita, Saki Matsumoto, Yujiro Nakajima, Miyuki Nagai, Ayako Tonari, Takeshi Ebara

Journal of Applied Clinical Medical Physics · 2024-02 · 25 (2)

DOI: 10.1002/acm2.14158 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 18.09.2023. Verfasst von Hiromi Enomoto und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Kyorin University Hospital, Mitaka, Tokyo, Japan. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Spinal Neoplasms, Prostatic Neoplasms, Brain Neoplasms. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Department of Radiation Oncology, Kyorin University, Komazawa University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optimizing the positional accuracy of multileaf collimators (MLC) for radiotherapy is important for dose accuracy and for reducing doses delivered to normal tissues. This study investigates dose sensitivity variations and complexity metrics of MLC positional error in volumetric modulated arc therapy and determines the acceptable ranges of MLC positional accuracy in several clinical situations. Treatment plans were generated for four treatment sites (prostate cancer, lung cancer, spinal, and brain metastases) using different treatment planning systems (TPSs) and fraction sizes. Each treatment plan introduced 0.25–2.0 mm systematic or random MLC leaf bank errors. The generalized equivalent uniform dose (gEUD) sensitivity and complexity metrics (MU/Gy and plan irregularity) were calculated, and the correlation coefficients were assessed. Furthermore, the required tolerances for MLC positional accuracy control were calculated. The gEUD sensitivity showed the highest dependence of systematic positional error on the treatment site, followed by TPS and fraction size. The gEUD sensitivities were 6.7, 4.5, 2.5, and 1.7%/mm for Monaco and 8.9, 6.2, 3.4, and 2.3%/mm (spinal metastasis, lung cancer, prostate cancer, and brain metastasis, respectively) for RayStation. The gEUD sensitivity was strongly correlated with the complexity metrics ( r = 0.88–0.93). The minimum allowable positional error for MLC was 0.63, 0.34, 1.02, and 0.28 mm (prostate, lung, brain, and spinal metastasis, respectively). The acceptable range of MLC positional accuracy depends on the treatment site, and an appropriate tolerance should be set for each treatment site with reference to the complexity metric. It is expected to enable easier and more detailed MLC positional accuracy control than before by reducing dose errors to patients at the treatment planning stage and by controlling MLC quality based on complexity metrics, such as MU/Gy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy, Intensity-ModulatedSpinal NeoplasmsProstatic NeoplasmsBrain NeoplasmsLung NeoplasmsMaleHumansRadiotherapy Planning, Computer-AssistedRadiotherapy Dosage

Stichwörter der Autor:innen

MLC positional errorVMATdose errorplan complexityplanning

Autor:innen und Institutionen

  • Department of Radiology, Kyorin University Hospital, Mitaka, Tokyo, Japan.
  • Department of Radiological Sciences, Komazawa University, Setagaya, Tokyo, Japan.
  • Department of Radiation Oncology, Kyorin University, Mitaka, Tokyo, Japan.
  • Department of Medical Radiological Technology, Faculty of Health Sciences, Kyorin University, Mitaka, Tokyo, Japan.

ORCID-Profile: Hiromi Enomoto

Förderung

  • Department of Radiation Oncology, Kyorin University
  • Komazawa University

Zitieren

APA

Enomoto, H., Fujita, Y., Matsumoto, S., Nakajima, Y., Nagai, M., Tonari, A., & Ebara, T. (2024). Dosimetric impact of MLC positional errors on dose distribution in IMRT. Journal of Applied Clinical Medical Physics, 25(2). https://doi.org/10.1002/acm2.14158

Vancouver

Enomoto H, Fujita Y, Matsumoto S, Nakajima Y, Nagai M, Tonari A, et al. Dosimetric impact of MLC positional errors on dose distribution in IMRT. Journal of Applied Clinical Medical Physics. 2024;25(2). doi:10.1002/acm2.14158

BibTeX
@article{Enomoto2024,
  author = {Enomoto, Hiromi and Fujita, Yukio and Matsumoto, Saki and Nakajima, Yujiro and Nagai, Miyuki and Tonari, Ayako and Ebara, Takeshi},
  title = {Dosimetric impact of MLC positional errors on dose distribution in IMRT},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  volume = {25},
  number = {2},
  doi = {10.1002/acm2.14158}
}
Kostenlos starten →