Dosimetric impact of hollow intraoral stents for head and neck cancer radiotherapy: A phantom study
Journal of Applied Clinical Medical Physics · 2023
DOI: 10.1002/acm2.14101 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2023. Verfasst von Hongbing Song und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiotherapy, Renmin Hospital of Wuhan University, Wuhan, Hubei, China. Hauptthemen laut MEDLINE: Head and Neck Neoplasms, Radiotherapy, Conformal, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hubei Key Laboratory Project of Renmin Hospital of Wuhan University, The Interdisciplinary Innovative Talents Foundation from Renmin Hospital of Wuhan University, Research Foundation on Cutting-edge Cancer Supportive Care.
Abstract (Originalsprache)
Purpose
To investigate the dosimetric impact of the calculation boundaries and dose calculation algorithms of radiotherapy in head and neck cancer patients with an opened oral cavity connected to the exterior by a hollow intraoral positioning stent. Methods and Materials A homemade silicone phantom with an opened oral cavity was placed in a CIRS head phantom to model head and neck cancer patients with a hollow intraoral positioning stent. 3D‐CRT plans were designed on CT images of the phantom in Monaco and Pinnacle 3 treatment planning systems (TPSs) with the same beam parameters. The default boundary and manually extrapolated boundary were both adopted in these two TPSs to explore the dosimetric impact on treatment plans. The nanoDot™ optically stimulated luminescence dosimeters (OSLDs) were chosen to measure the planned dose surrounding the oral cavity of the head phantom after calibration.
Result
The doses in the air cavity and two measuring points at the joint area were dramatically changed from 0.0, 92.4 and 148.8 cGy to 177.8, 244.2 and 244.1 cGy in Monaco after adopting the extrapolated boundary. While the calculated doses at the same place were changed from 61.2, 143.7 and 198.3 cGy to 175.4, 234.7 and 233.2 cGy in Pinnacle 3 with a similar calculation boundary. For the Monaco TPS, the relative errors compared to the OSLD measured doses were 2.94 ± 1.93%, 0.53 ± 8.64%, 2.65 ± 1.87% and 3.93 ± 1.69% at 4 measuring positions. In contrast, the relative errors 4.03 ± 1.93%, 4.85 ± 8.64%, 7.61 ± 1.87% and 5.61 ± 1.69% were observed in Pinnacle 3 .
Conclusion
The boundary setting of an opened oral cavity in TPSs has a significant dosimetric impact on head and neck cancer radiotherapy. An extrapolated boundary should be manually set up to include the whole oral cavity in the dose calculation domain to avoid major dose deviations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiotherapy, Renmin Hospital of Wuhan University, Wuhan, Hubei, China.
- Department of Radiology, Union Hospital, TongJi Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
Förderung
- Hubei Key Laboratory Project of Renmin Hospital of Wuhan University
- The Interdisciplinary Innovative Talents Foundation from Renmin Hospital of Wuhan University
- Research Foundation on Cutting-edge Cancer Supportive Care
- Natural Science Foundation of Hubei Province
- Health and Family Planning Commission of Hubei Province
- Cisco hausen Cancer Research Foundation
Zitieren
APA
Song, H., Hu, J., He, J., Ma, G., Cheng, L., & Li, X. (2023). Dosimetric impact of hollow intraoral stents for head and neck cancer radiotherapy: A phantom study. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14101
Vancouver
Song H, Hu J, He J, Ma G, Cheng L, Li X. Dosimetric impact of hollow intraoral stents for head and neck cancer radiotherapy: A phantom study. Journal of Applied Clinical Medical Physics. 2023. doi:10.1002/acm2.14101
BibTeX
@article{Song2023,
author = {Song, Hongbing and Hu, Jian and He, Junxiang and Ma, Guangdong and Cheng, Lan and Li, Xiangpan},
title = {Dosimetric impact of hollow intraoral stents for head and neck cancer radiotherapy: A phantom study},