EUVIMEDEUVIMED entdecken
Crossref

Dosimetric and radiobiological advantages from deep inspiration breath-hold and free breath technique for left-sided breast radiation using 3DCRT, IMRT and Rapid Arc methods—a complete assessment

Sougoumarane Dashnamoorthy, Ebenezar Jeyasingh, Karthick Rajamanickam, Venkatraman Pitchaikannu, Kathiresan Nachimuthu

Radiation Protection Dosimetry · 2024

DOI: 10.1093/rpd/ncae075 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Sougoumarane Dashnamoorthy und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiotherapy, Thangam Cancer Hospital, Namakkal 637001, Tamil Nadu, India. Hauptthemen laut MEDLINE: Breath Holding, Radiotherapy, Intensity-Modulated, Radiotherapy Planning, Computer-Assisted, Radiotherapy Dosage. Die Arbeit nennt 44 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The verification and use of the best treatment approach using 3D conformal radiation therapy (3DCRT), intensity modulated radiation therapy (IMRT) and Rapid Arc methods for left breast radiation with dosimetric and radiobiological characteristics. The use of custom-built Python software for the estimation and comparison of volume, mean dose, maximum dose, monitor units and normal tissue integral dose along with radiobiological parameters such as NTCP, tumor control probability, equivalent uniform dose and LKB’s effective volume from 3DCRT, IMRT and Rapid Arc planning with deep inspiration with breath holding (DIBH) and free breadth (FB) techniques. Volume growth of three-fourth in DIBH compared with FB causes a decrease in cardiac doses and complications because the left lung expands, pulling the heart away from the chest wall and the treatment area. A tiny area of the left lung was exposed during treatment, which reduced the mean dose. There was little difference in the treatment approaches because the spinal cord was immobile in both techniques. Rapid Arc is the unmatched modality for left-sided breast irradiation with significant patient breath-hold, as shown by the comparison of dosimetric and radiobiological parameters from treatment techniques with a deep inspiration breath-hold approach.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breath HoldingRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedRadiotherapy DosageUnilateral Breast NeoplasmsRadiotherapy, ConformalOrgans at RiskHumansFemaleRadiometry

Autor:innen und Institutionen

  • Department of Radiotherapy, Thangam Cancer Hospital, Namakkal 637001, Tamil Nadu, India.
  • PG & Research Department of Physics, Jamal Mohamed College (Autonomous), Affiliated to Bharathidasan University, Tiruchirappalli 620020, Tamil Nadu, India.
  • Department of Medical Physics, Bharathidasan University, Trichy 620024, India.

Zitieren

APA

Dashnamoorthy, S., Jeyasingh, E., Rajamanickam, K., Pitchaikannu, V., & Nachimuthu, K. (2024). Dosimetric and radiobiological advantages from deep inspiration breath-hold and free breath technique for left-sided breast radiation using 3DCRT, IMRT and Rapid Arc methods—a complete assessment. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae075

Vancouver

Dashnamoorthy S, Jeyasingh E, Rajamanickam K, Pitchaikannu V, Nachimuthu K. Dosimetric and radiobiological advantages from deep inspiration breath-hold and free breath technique for left-sided breast radiation using 3DCRT, IMRT and Rapid Arc methods—a complete assessment. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae075

BibTeX
@article{Dashnamoorthy2024,
  author = {Dashnamoorthy, Sougoumarane and Jeyasingh, Ebenezar and Rajamanickam, Karthick and Pitchaikannu, Venkatraman and Nachimuthu, Kathiresan},
  title = {Dosimetric and radiobiological advantages from deep inspiration breath-hold and free breath technique for left-sided breast radiation using 3DCRT, IMRT and Rapid Arc methods—a complete assessment},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  doi = {10.1093/rpd/ncae075}
}
Kostenlos starten →