EUVIMEDEUVIMED entdecken
Crossref

Feasibility, Treatment Planning, and Clinical Results of VMAT‐Based Total Body Irradiation for Pediatric Patients: Single‐Center Experience

Soraya Mico iD, Marcelino Hermida-López iD, Mónica Ramos-Albiac iD, Savannah Pié-Padró, Pau Guardiola-Zaragoza iD, Paula Navarro-Palomas iD, Antonio Jurado, David García, Jordi Giralt iD

Pediatric Blood & Cancer · 2026-10 · 73 (10)

DOI: 10.1002/1545-5017.70629 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatric Blood & Cancer, online erschienen am 17.08.2026. Verfasst von Soraya Mico und 8 weiteren Autor:innen. Beteiligte Einrichtung: Servei d'Oncologia Radioteràpica, Hospital Universitari Vall d'Hebron, Barcelona, Spain. Hauptthemen laut MEDLINE: Whole-Body Irradiation, Radiotherapy, Intensity-Modulated, Radiotherapy Planning, Computer-Assisted, Precursor Cell Lymphoblastic Leukemia-Lymphoma. Die Arbeit nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Purpose Total body irradiation (TBI) is a standard component of conditioning regimens for pediatric patients with acute lymphoblastic leukemia (ALL) undergoing hematopoietic stem cell transplantation (HSCT). Volumetric modulated arc therapy (VMAT) has emerged as a promising technique to improve dose conformity and organ‐at‐risk (OAR) sparing. This study evaluates the feasibility, dosimetric performance, and acute toxicity of a VMAT‐based TBI (VMAT‐TBI) technique implemented in a pediatric population. Materials and Methods Fifteen pediatric patients treated with myeloablative VMAT‐TBI between August 2019 and December 2024 were retrospectively analyzed. Prescription regimens ranged from 9.9 to 12 Gy, delivered in three to six fractions. Planning objectives followed ESTRO–ACROP–SIOPE recommendations, with mean lung dose less than 8 Gy and mean kidney dose less than 10 Gy. Dosimetric coverage, OAR sparing, patient‐specific quality assurance, image‐guided verification, and clinical outcomes were assessed.

Results

All treatment plans achieved adequate target coverage (mean PTV D95% = 96.6% ± 2.5%), with V110% = 19.1% ± 11.2% and V120% less than 1%. Mean lung and kidney doses were 7.8 ± 0.7 and 8.9 ± 1.1 Gy, respectively. Planned and measured dose distributions showed excellent agreement (gamma passing rates with 3%/3 mm criteria of 96.2% ± 4.6% with ArcCHECK diode array). After a median follow‐up of 18 months, one late non‐infectious pulmonary toxicity and one severe renal toxicity were observed.

Conclusion

VMAT‐TBI is a feasible, effective technique for pediatric HSCT conditioning, providing excellent target coverage, OAR sparing, and acceptable toxicity. These findings support VMAT‐TBI as a viable alternative to conventional TBI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Whole-Body IrradiationRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedPrecursor Cell Lymphoblastic Leukemia-LymphomaHematopoietic Stem Cell TransplantationTransplantation ConditioningHumansFemaleChildMaleFeasibility StudiesRetrospective StudiesChild, PreschoolAdolescentOrgans at RiskRadiotherapy DosageFollow-Up StudiesInfantPrognosis

Stichwörter der Autor:innen

dosimetryhematopoietic stem cell transplantationorgan sparingpediatrictotal body irradiationvolumetric modulated arc therapy

Autor:innen und Institutionen

  • Servei d'Oncologia Radioteràpica, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
  • Servei de Física i Protecció Radiològica, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
  • Servei d'Oncologia Radioteràpica, Hospital Clínic de Barcelona, Barcelona, Spain.
  • Departament de Medicina, Universitat Autònoma de Barcelona, Barcelona, Spain.

ORCID-Profile: Soraya Mico, Marcelino Hermida-López, Mónica Ramos-Albiac, Pau Guardiola-Zaragoza, Paula Navarro-Palomas, Jordi Giralt

Zitieren

APA

Mico, S., Hermida-López, M., Ramos-Albiac, M., Pié-Padró, S., Guardiola-Zaragoza, P., Navarro-Palomas, P., Jurado, A., García, D., & Giralt, J. (2026). Feasibility, Treatment Planning, and Clinical Results of VMAT‐Based Total Body Irradiation for Pediatric Patients: Single‐Center Experience. Pediatric Blood & Cancer, 73(10). https://doi.org/10.1002/1545-5017.70629

Vancouver

Mico S, Hermida-López M, Ramos-Albiac M, Pié-Padró S, Guardiola-Zaragoza P, Navarro-Palomas P, et al. Feasibility, Treatment Planning, and Clinical Results of VMAT‐Based Total Body Irradiation for Pediatric Patients: Single‐Center Experience. Pediatric Blood & Cancer. 2026;73(10). doi:10.1002/1545-5017.70629

BibTeX
@article{Mico2026,
  author = {Mico, Soraya and Hermida-López, Marcelino and Ramos-Albiac, Mónica and Pié-Padró, Savannah and Guardiola-Zaragoza, Pau and Navarro-Palomas, Paula and Jurado, Antonio and García, David and Giralt, Jordi},
  title = {Feasibility, Treatment Planning, and Clinical Results of VMAT‐Based Total Body Irradiation for Pediatric Patients: Single‐Center Experience},
  journal = {Pediatric Blood & Cancer},
  year = {2026},
  volume = {73},
  number = {10},
  doi = {10.1002/1545-5017.70629}
}
Kostenlos starten →