Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Occupational Health, online erschienen am 10.12.2021. Verfasst von Keisuke Nagamoto und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Hospital of the University of Occupational and Environmental Health, Japan, Kitakyushu, Fukuoka, Japan. Hauptthemen laut MEDLINE: Lens, Crystalline, Physicians, Radiation Dosage, Radiology. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Ministry of Health, Labour and Welfare.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

We investigated occupational dose to the lens of the eye for physicians engaged in radiology procedures. We evaluated the potential for compliance with the new-equivalent dose limits to the lens of the eye. Further, a “multiple radiation protection” protocol was proposed according to the basic principles of occupational health, and its effectiveness was estimated.

Methods

Physicians engaged in radiology procedure at medical facilities in Japan were included in this study. The eye lens dose (3-mm dose equivalent: Hp(3)) for each participant was measured using a small radio-photoluminescence glass dosimeter mounted on lead glasses. Physicians were directed to procedure multiple radiation protection measures to evaluate their usefulness.

Results

The Hp(3) was reduced by multiple radiation protection in all physicians. In particular, the Hp(3) reduced from 207.7 to 43.2 μSv/procedure and from 21.6 to 10.2 μSv/procedure in cardiovascular internal physician and cerebrovascular physician, respectively, after the implementation of the proposed multiple radiation protection measures. The dose reduction rate of these measures was 53% (range: 37%–79%).

Conclusions

The radiation doses received by the eye lenses of physicians engaged in radiology procedure may exceed the dose limits to the lens of the eye if radio-protective equipment and imaging conditions are not properly controlled. However, based on the lens equivalent dose data, the implementation of “multiple radiation protection” according to the basic principles of occupational health can ensure compliance with the new-equivalent dose limits to the lens of the eye without placing an undue burden on individual physicians or medical facilities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lens, CrystallinePhysiciansRadiation DosageRadiologyHumansJapan

Stichwörter der Autor:innen

eye lens dosemultiple radiation protectionoccupational exposureradio-photoluminescence glass dosimetersradiology procedures

Autor:innen und Institutionen

  • Department of Radiology, Hospital of the University of Occupational and Environmental Health, Japan, Kitakyushu, Fukuoka, Japan.
  • Department of Radiation Regulatory Research Group, National Institute of Radiological Sciences, Quantum Life and Medical Science Directorate, National Institute for Quantum and Radiological Science and Technology, Chiba…
  • Department of Occupational and Community Health Nursing School of Health Sciences, University of Occupational and Environmental Health, Japan, Kitakyushu, Fukuoka, Japan.
  • Department of Radiology, Shinkomonji Hospital, Kitakyushu, Fukuoka, Japan.

ORCID-Profile: Keisuke Nagamoto, Naoki Kunugita

Förderung

  • Japan Society for the Promotion of Science
  • Ministry of Health, Labour and Welfare

Zitieren

APA

Nagamoto, K., Moritake, T., Nakagami, K., Morota, K., Matsuzaki, S., & Kunugita, N. (2021). A multicenter study of radiation doses to the eye lenses of clinical physicians performing radiology procedures in Japan. Journal of Occupational Health, 63(1). https://doi.org/10.1002/1348-9585.12305

Vancouver

Nagamoto K, Moritake T, Nakagami K, Morota K, Matsuzaki S, Kunugita N. A multicenter study of radiation doses to the eye lenses of clinical physicians performing radiology procedures in Japan. Journal of Occupational Health. 2021;63(1). doi:10.1002/1348-9585.12305

BibTeX
@article{Nagamoto2021,
  author = {Nagamoto, Keisuke and Moritake, Takashi and Nakagami, Koichi and Morota, Koichi and Matsuzaki, Satoru and Kunugita, Naoki},
  title = {A multicenter study of radiation doses to the eye lenses of clinical physicians performing radiology procedures in Japan},
  journal = {Journal of Occupational Health},
  year = {2021},
  volume = {63},
  number = {1},
  doi = {10.1002/1348-9585.12305}
}
Kostenlos starten →