Performance Evaluation And Optimization Of Injection Molding Using Hybrid Conformal Cooling Channels
IOSR Journal of Mechanical and Civil Engineering · 2026-01 · 23 (1) · 72-78
DOI: 10.9790/1684-2301017278 ↗Kurz gefasst
Fachartikel in der Zeitschrift IOSR Journal of Mechanical and Civil Engineering, 2026-01. Verfasst von Prof. Pankaj Dhoble und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Injection molding performance is strongly influenced by part shrinkage and cycle time, which directly affect product quality and manufacturing efficiency. Optimizing these outcomes requires careful control of processing parameters and effective cooling channel design. Multi-objective optimization techniques provide a systematic approach to improving molding performance. Materials and Methods: This study applied a Taguchi-based Grey Relational Analysis (GRA) technique to optimize injection molding parameters. Experiments were conducted on a 100-ton Electronica injection molding machine using LDPE material to manufacture components with a diameter of 30 mm. Three cooling approaches were evaluated: traditional cooling channels, porous conformal cooling channels, and hybrid conformal cooling channels. Injection pressure, injection temperature, and coolant flow rate were selected as input parameters. Shrinkage and cycle time were considered as performance responses.
Results
The analysis showed that the hybrid conformal cooling channel design achieved the highest Grey Relational Grade, indicating superior overall performance compared to the other cooling strategies. Optimal parameter combinations were identified for each cooling method. The results also revealed that cooling channel design and injection pressure had a significant influence on both shrinkage reduction and cycle time improvement.
Conclusion
The study confirms that the Taguchi-GRA approach is effective for simultaneous optimization of multiple quality characteristics in injection molding. Hybrid conformal cooling channels provide notable advantages in reducing shrinkage and cycle time. The findings offer practical guidance for mold design improvement and enhanced process control in industrial injection molding applications.
Zitieren
APA
Dhoble, P. P., Deshmukh, D. R. R. D. D. R. R., & Bargir, M. A. N. (2026). Performance Evaluation And Optimization Of Injection Molding Using Hybrid Conformal Cooling Channels. IOSR Journal of Mechanical and Civil Engineering, 23(1), 72-78. https://doi.org/10.9790/1684-2301017278
Vancouver
Dhoble PP, Deshmukh DRRDDRR, Bargir MAN. Performance Evaluation And Optimization Of Injection Molding Using Hybrid Conformal Cooling Channels. IOSR Journal of Mechanical and Civil Engineering. 2026;23(1):72-78. doi:10.9790/1684-2301017278
BibTeX
@article{Dhoble2026,
author = {Dhoble, Prof. Pankaj and Deshmukh, Dr. R. R. Deshmukh Dr. R. R. and Bargir, Md. Azar Nisar},
title = {Performance Evaluation And Optimization Of Injection Molding Using Hybrid Conformal Cooling Channels},
journal = {IOSR Journal of Mechanical and Civil Engineering},
year = {2026},
volume = {23},
number = {1},
pages = {72--78},
doi = {10.9790/1684-2301017278}
}
EUVIMED