EUVIMEDEUVIMED entdecken
Crossref

Examination of Permeation Resistance of Chemical Protective Gloves Made of Laminate-Film Materials Against Chemical Substances

Takamasa Aoki, Hiroyuki Miyauchi

Journal of UOEH · 2024

DOI: 10.7888/juoeh.46.9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of UOEH, 2024. Verfasst von Takamasa Aoki und 1 weiteren Autor:innen. Beteiligte Einrichtung: Campus life Support Service Headquarters, Kyushu Institute of Technology, Kitakyushu, Japan. Hauptthemen laut MEDLINE: Gloves, Protective, Occupational Exposure. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigated the permeation resistance of chemical protective gloves made of laminate film comprising nylon, ethylene-vinyl alcohol copolymer (EVOH), and other materials against different chemical substances to examine their usability in different work processes. The permeation resistance of the chemical protective glove was tested using the Japanese Industrial Standards (JIS) test method against twelve substances: acetone, acetonitrile, dichloromethane, ethyl acetate, n-hexane, methanol, tetrahydrofuran, toluene, 2-propanol, 1-butanol, 1,4-diethylene dioxide, and ethanol. After 480 min, no substance, except for methanol and ethanol, permeated at a standard permeation rate of 0.1 μg/cm2/min. Methanol and ethanol showed permeation at 1 min and 30 min elapsed, respectively. Hence, the gloves tested in this study exhibited permeation resistance to various chemical substances, and can thus be used in many work processes. Some film materials have short permeation time against certain chemical substances, but the chemical protective gloves tested in this study can be used at work sites, such as manufacturing sites, that require permeation resistance to different chemical substances.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Gloves, ProtectiveOccupational ExposureMethanolEthanolAcetoneToluene

Stichwörter der Autor:innen

chemical protective glovelaminate filmorganic solventpermeation resistance

Substanzen

MethanolEthanolAcetoneToluene

Autor:innen und Institutionen

  • Campus life Support Service Headquarters, Kyushu Institute of Technology, Kitakyushu, Japan.
  • Environmental Measurement and Control, School of Health Sciences, University of Occupational and Environmental Health, Japan.

Zitieren

APA

Aoki, T., & Miyauchi, H. (2024). Examination of Permeation Resistance of Chemical Protective Gloves Made of Laminate-Film Materials Against Chemical Substances. Journal of UOEH. https://doi.org/10.7888/juoeh.46.9

Vancouver

Aoki T, Miyauchi H. Examination of Permeation Resistance of Chemical Protective Gloves Made of Laminate-Film Materials Against Chemical Substances. Journal of UOEH. 2024. doi:10.7888/juoeh.46.9

BibTeX
@article{Aoki2024,
  author = {Aoki, Takamasa and Miyauchi, Hiroyuki},
  title = {Examination of Permeation Resistance of Chemical Protective Gloves Made of Laminate-Film Materials Against Chemical Substances},
  journal = {Journal of UOEH},
  year = {2024},
  doi = {10.7888/juoeh.46.9}
}
Kostenlos starten →