EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Developing a device to determine the permeation of chemicals through whole protective boots

Hiroyuki Miyauchi iD, Shinobu Yamanoto iD, Takamasa Aoki iD

Journal of Occupational Health · 2025

DOI: 10.1093/joccuh/uiaf031 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Occupational Health, 2025. Verfasst von Hiroyuki Miyauchi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Occupational Hygiene, School of Health Science, University of Occupational and Environmental Health, Kitakyushu, Japan. Hauptthemen laut MEDLINE: Shoes, Materials Testing, Protective Clothing, Occupational Exposure. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To develop a device to evaluate the permeation resistance of chemical-protective boots continuously in contact with liquid chemicals, and to compare the permeation time of the component material test pieces with the permeation time of the whole boot and thus evaluate its performance.

Methods

The permeation time was calculated for toluene, dichloromethane, and acetone in 4 types of boot, according to Japanese Industrial Standard (JIS) T 8117:2005.

Results

The permeation test for whole boots showed shorter permeation times than those of the component materials, according to JIS T 8117:2005. The permeation time of toluene was more than twice that of boots C and D. The permeation time of dichloromethane was more than twice that of boots A and C and more than 3 times shorter for boot A.

Conclusions

The differences between the whole-boot tests and the material tests were thought to be related to variations in thickness, type of material, difference in adhesion, and penetration from pinwheels. This method enables the determination of the permeation of chemicals and other performance characteristics of the whole boot, which cannot be determined using testing of material specimens alone. By using this device for testing, appropriate boots that are protective against specific chemicals and can prevent chemically induced damage to the feet can be more efficiently selected.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ShoesMaterials TestingProtective ClothingOccupational ExposurePermeabilityTolueneHumansAcetoneMethylene Chloride

Stichwörter der Autor:innen

chemical-protective bootspermeation testpermeation timetoluenewhole chemical resistant

Substanzen

TolueneAcetoneMethylene Chloride

Autor:innen und Institutionen

  • Department of Occupational Hygiene, School of Health Science, University of Occupational and Environmental Health, Kitakyushu, Japan.
  • Organization for Health Support and Promotion of Environment and Safety, Kyushu Institute of Technology, Kitakyushu, Japan.

ORCID-Profile: Hiroyuki Miyauchi, Shinobu Yamanoto, Takamasa Aoki

Zitieren

APA

Miyauchi, H., Yamanoto, S., & Aoki, T. (2025). Developing a device to determine the permeation of chemicals through whole protective boots. Journal of Occupational Health. https://doi.org/10.1093/joccuh/uiaf031

Vancouver

Miyauchi H, Yamanoto S, Aoki T. Developing a device to determine the permeation of chemicals through whole protective boots. Journal of Occupational Health. 2025. doi:10.1093/joccuh/uiaf031

BibTeX
@article{Miyauchi2025,
  author = {Miyauchi, Hiroyuki and Yamanoto, Shinobu and Aoki, Takamasa},
  title = {Developing a device to determine the permeation of chemicals through whole protective boots},
  journal = {Journal of Occupational Health},
  year = {2025},
  doi = {10.1093/joccuh/uiaf031}
}
Kostenlos starten →