EUVIMEDEUVIMED entdecken
Open Access

A Preliminary Feasibility Study on Hemodynamic Changes Following Feyh-Kastenbauer Retractor Insertion During Transoral Robotic Surgeries

Nitika Goel, Sonali Kaushal, Deepanshu Dhiman, Naresh K Panda, Tanvir Samra

Cureus · 09.05.2023

DOI: 10.7759/cureus.38804 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cureus, erschienen am 09.05.2023. Verfasst von Nitika Goel und 4 weiteren Autor:innen. Beteiligte Einrichtung: Anaesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, IND. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Transoral robotic surgery (TORS) has become increasingly popular for the removal of pharyngeal and laryngeal cancers with the objective to improve functional and aesthetic outcomes. Feyh-Kastenbauer (FK) retractor is one such routinely used retractor during TORS. The setting up of this retractor has been seen to be accompanied by hemodynamic fluctuations. Methodology This prospective observational study was carried out on 30 patients undergoing TORS. All patients were administered general anesthesia using a pre-defined anesthesia protocol. The primary outcome was to compare hemodynamic fluctuations following endotracheal intubation with that after FK retractor insertion. Any requirement of a bolus dose of sevoflurane and fentanyl was recorded in response to hemodynamic fluctuations recorded in secondary outcomes.

Results

There was no statistically significant increase in mean heart rate, systolic, diastolic, and mean arterial blood pressure from baseline to endotracheal intubation and following retractor insertion (p=0.810, p=0.2, p=0.6, p=0.3 respectively). On subgroup analysis, hypertensive patients reported a greater rise in blood pressure following two minutes post FK retractor insertion compared to non-hypertensive patients (p=0.03). Out of 30 patients, five patients required a bolus dose of sevoflurane.

Conclusion

FK retractor insertion had a comparable hemodynamic response as endotracheal intubation during TORS. Hypertensive patients showed a rise in blood pressure at both endotracheal intubations and at FK retractor insertion.

Schlagwörter

Stichwörter der Autor:innen

fentanylfeyh-kastenbauer retractorhemodynamic changessevofluranetransoral robotic surgery

Autor:innen und Institutionen

  • Anaesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, IND.
  • Anaesthesia, Dr. Yashwant Singh (YS) Parmar Medical College and Hospital, Nahan, IND.
  • Otolaryngology, Postgraduate Institute of Medical Education and Research, Chandigarh, IND.

Zitieren

APA

Goel, N., Kaushal, S., Dhiman, D., Panda, N. K., & Samra, T. (2023). A Preliminary Feasibility Study on Hemodynamic Changes Following Feyh-Kastenbauer Retractor Insertion During Transoral Robotic Surgeries. Cureus. https://doi.org/10.7759/cureus.38804

Vancouver

Goel N, Kaushal S, Dhiman D, Panda NK, Samra T. A Preliminary Feasibility Study on Hemodynamic Changes Following Feyh-Kastenbauer Retractor Insertion During Transoral Robotic Surgeries. Cureus. 2023. doi:10.7759/cureus.38804

BibTeX
@article{Goel2023,
  author = {Goel, Nitika and Kaushal, Sonali and Dhiman, Deepanshu and Panda, Naresh K and Samra, Tanvir},
  title = {A Preliminary Feasibility Study on Hemodynamic Changes Following Feyh-Kastenbauer Retractor Insertion During Transoral Robotic Surgeries},
  journal = {Cureus},
  year = {2023},
  doi = {10.7759/cureus.38804}
}
Kostenlos starten →