Effect of intraoral glossopharyngeal nerve block on hemodynamic response to mouth retractor placement in transoral robotic surgery: a randomized clinical trial
Journal of Robotic Surgery · 28.10.2026 · 20 (1)
DOI: 10.1007/s11701-026-04087-w ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Journal of Robotic Surgery, online erschienen am 28.10.2026. Verfasst von Ankita Bhasin und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesia and Intensive Care, Government Medical College and Hospital, Sector 32, Chandigarh, 160030, India. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Nerve Block, Hemodynamics, Glossopharyngeal Nerve. Die Arbeit nennt 16 Literaturangaben.
Abstract (Originalsprache)
Placement of rigid oral retractors during transoral robotic surgery (TORS) elicits a sympathetic hemodynamic response that may be harmful in high-risk patients. The glossopharyngeal nerve provides sensory innervation to the oropharyngeal structures stimulated during retractor placement, yet no previous trial has evaluated glossopharyngeal nerve block (GPN block) for attenuating this response. In this prospective, single-center, randomized clinical trial, 42 patients (ASA I-II, aged 18–65 years) undergoing TORS were allocated 1:1 to the block group, which received bilateral intraoral GPN block with 2 mL of 2% lignocaine per side or the Control group, which received no block. The outcome assessor was blinded; no sham procedure was performed, and the anaesthesiologist performing the block was not blinded. The primary outcome was the proportion of patients with a > 20% increase in mean arterial pressure (MAP) from the pre-retractor baseline within 10 minutes of Feyh-Kastenbauer retractor insertion. Bayesian logistic regression with a Normal (0, 5) prior on the group coefficient was used; the pre-specified decision criterion was a posterior probability of directional benefit P (ARD 20% occurred in 8 of 21 patients (38.1%) in the control group versus 3 of 21 (14.3%) in the block group. The posterior mean absolute risk difference was − 23.9% (95% credible interval [CrI]: − 49.4% to 2.2%), with P (ARD < 0) = 0.964, exceeding the pre-specified threshold. Sensitivity analyses generally supported the direction of effect under neutral, sceptical, and optimistic priors (P(ARD < 0) range: 0.934–0.967), although the posterior probability under the sceptical prior did not exceed the prespecified 0.95 threshold; evidence was equivocal under the pessimistic prior (P(ARD < 0) = 0.57). Maximum MAP and heart rate were lower in the block group (P (difference < 0) = 0.998 and 0.995, respectively). Bispectral index values were comparable between groups throughout the procedure. The GPN block is associated with a high posterior probability of attenuating the hemodynamic response to mouth retractor placement in TORS. The credible intervals were wide, reflecting uncertainty about effect magnitude. A larger confirmatory trial assessing clinical endpoints is warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesia and Intensive Care, Government Medical College and Hospital, Sector 32, Chandigarh, 160030, India.
- Department of Anesthesia & Intensive Care, Post Graduate Institute of Medical Education and Research, Sector 12, Chandigarh, 160012, India.
- Department of Anesthesia & Intensive Care, Post Graduate Institute of Medical Education and Research, Sector 12, Chandigarh, 160012, India. ajay.ydv2509@gmail.com.
- Department of Otolaryngology and Head and Neck Surgery, Post Graduate Institute of Medical Education and Research, Sector 12, Chandigarh, 160012, India.
- Department of Ear, Nose, and Throat, Max Super Specialty Hospital, Mohali, Punjab, 160055, India.
Zitieren
APA
Bhasin, A., Ganesh, V., Singh, A., Naik, N. B., Soni, S. L., Kaloria, N., Patro, S. K., & Panda, N. K. (2026). Effect of intraoral glossopharyngeal nerve block on hemodynamic response to mouth retractor placement in transoral robotic surgery: a randomized clinical trial. Journal of Robotic Surgery, 20(1). https://doi.org/10.1007/s11701-026-04087-w
Vancouver
Bhasin A, Ganesh V, Singh A, Naik NB, Soni SL, Kaloria N, et al. Effect of intraoral glossopharyngeal nerve block on hemodynamic response to mouth retractor placement in transoral robotic surgery: a randomized clinical trial. Journal of Robotic Surgery. 2026;20(1). doi:10.1007/s11701-026-04087-w
BibTeX
@article{Bhasin2026,
author = {Bhasin, Ankita and Ganesh, Venkata and Singh, Ajay and Naik, Naveen B and Soni, Shiv Lal and Kaloria, Narender and Patro, Sourabha K and Panda, Naresh K},
title = {Effect of intraoral glossopharyngeal nerve block on hemodynamic response to mouth retractor placement in transoral robotic surgery: a randomized clinical trial},
journal = {Journal of Robotic Surgery},
year = {2026},
volume = {20},
number = {1},
doi = {10.1007/s11701-026-04087-w}
}
EUVIMED