EUVIMEDEUVIMED entdecken
Open Access

A Tensile Test-Based Investigation of Load Deflection Properties of Three Commercial Superelastic Nickel-Titanium Orthodontic Archwires: An In Vitro Study

Ravisankar Vijayan, Latheef Vadakkepediyakkal, Jayan James

Cureus · 05.08.2026

DOI: 10.7759/cureus.114032 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cureus, erschienen am 05.08.2026. Verfasst von Ravisankar Vijayan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Orthodontics and Dentofacial Orthopaedics, Government Dental College, Thrissur, Thrissur, IND. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Nickel-titanium (Ni-Ti) alloys are widely used during the initial alignment phase of fixed orthodontic treatment because of their ability to deliver light and relatively constant forces over a wide range of activation. This study compared the force values at predetermined deflections of three commercially available super-elastic Ni-Ti archwire brands: 3M Unitek (Solventum Orthodontics Corporation, Monrovia, California, United States), G&H (G&H Orthodontics, Franklin, Indiana, United States), and DTech (D-Tech Dental Technologies, Pune, Maharashtra, India). MATERIALS AND METHODS: Preformed straight length 0.019 × 0.025-inch super-elastic Ni-Ti archwires from three manufacturers were evaluated. Specimens were divided into three groups: Group I (3M Unitek), Group II (G&H), and Group III (D-Tech). A three-point bending test was performed to assess load-deflection characteristics. Load values were recorded at 0.5 mm and 1.0 mm deflection during loading and at 0.5 mm deflection during unloading. Intergroup comparisons were performed using appropriate statistical tests. RESULTS: A statistically significant difference among the three brands was observed at 0.5 mm loading. Group III demonstrated the highest mean rank, followed by Group II and Group I, indicating higher loading forces at this level of deflection. No statistically significant differences were found among the groups at 1.0 mm loading or 0.5 mm unloading. Pairwise analysis revealed a significant difference between Groups III and I, whereas differences between Groups III and II and between Groups II and I were not significant. CONCLUSION: Differences in load-deflection behaviour were observed among the tested archwires, particularly at 0.5 mm loading. Group III exhibited higher loading-force values than Group II and Group I, with Group III showing the lowest, while no significant differences were identified at 1.0 mm loading or 0.5 mm unloading. These findings indicate variations in mechanical performance among commercially available super-elastic Ni-Ti archwires; however, clinical trials are required before drawing conclusions regarding clinical performance or superiority.

Schlagwörter

Stichwörter der Autor:innen

alignmentload deflection ratemechanical propertiesnickel titanium archwiressuper-elastic wires

Autor:innen und Institutionen

  • Orthodontics and Dentofacial Orthopaedics, Government Dental College, Thrissur, Thrissur, IND.
  • Orthodontics and Dentofacial Orthopaedics, Government Dental College, Kozhikode, Kozhikode, IND.
  • Orthodontics and Dentofacial Orthopaedics, Government Dental College, Kottayam, Kottayam, IND.

Zitieren

APA

Vijayan, R., Vadakkepediyakkal, L., & James, J. (2026). A Tensile Test-Based Investigation of Load Deflection Properties of Three Commercial Superelastic Nickel-Titanium Orthodontic Archwires: An In Vitro Study. Cureus. https://doi.org/10.7759/cureus.114032

Vancouver

Vijayan R, Vadakkepediyakkal L, James J. A Tensile Test-Based Investigation of Load Deflection Properties of Three Commercial Superelastic Nickel-Titanium Orthodontic Archwires: An In Vitro Study. Cureus. 2026. doi:10.7759/cureus.114032

BibTeX
@article{Vijayan2026,
  author = {Vijayan, Ravisankar and Vadakkepediyakkal, Latheef and James, Jayan},
  title = {A Tensile Test-Based Investigation of Load Deflection Properties of Three Commercial Superelastic Nickel-Titanium Orthodontic Archwires: An In Vitro Study},
  journal = {Cureus},
  year = {2026},
  doi = {10.7759/cureus.114032}
}
Kostenlos starten →