EUVIMEDEUVIMED entdecken
Open Access

Comparative Evaluation of the Accuracy of an Electronic Apex Locator Using Two Different Canal Conditions: An In Vitro Study

Mohd Zeeshan Ahmad, Divyangana Thakur, Megha Ghosh, Ritika Chaudhary, Anuradha Reddy, Twinkle Gupta

Cureus · 15.05.2026

DOI: 10.7759/cureus.108889 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cureus, erschienen am 15.05.2026. Verfasst von Mohd Zeeshan Ahmad und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry and Endodontics, Rama Dental College Hospital and Research Center, Kanpur, IND. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Accurate determination of the working length is critical for the success of root canal treatment, as it ensures effective cleaning, shaping, and obturation of the root canal system. Electronic apex locators are widely used for this purpose; however, their accuracy may be influenced by intracanal conditions, particularly the presence or absence of irrigation solutions. This study aimed to evaluate and compare the accuracy of a third-generation apex locator under dry, normal saline, and 3% sodium hypochlorite canal conditions. MATERIALS AND METHODS: This in vitro study was conducted on 45 extracted human single-rooted teeth randomly divided into three groups (n = 15 each) based on canal conditions: dry, normal saline, and 3% sodium hypochlorite. The actual working length (AWL) was determined visually and was used as the gold standard. The electronic working length (EWL) was measured using a Root ZX Mini. The difference between the EWL and AWL was calculated. Data were analyzed using one-way analysis of variance (ANOVA) followed by Tukey's post-hoc test, and categorical accuracy was assessed using the chi-square test, with significance set at p < 0.05. RESULTS: The normal saline group demonstrated the lowest mean deviation (0.21 ± 0.14 mm; 95% CI: 0.13-0.29), followed by the sodium hypochlorite group (0.34 ± 0.19 mm; 95% CI: 0.23-0.45), while the dry canal group showed the highest deviation (0.58 ± 0.22 mm; 95% CI: 0.46-0.70). A one-way ANOVA revealed a statistically significant difference between the groups (F = 18.74, p < 0.001). Post hoc analysis revealed significant differences between all groups (p < 0.05). The proportion of accurate measurements (±0.5 mm) was highest in the normal saline group, followed by the sodium hypochlorite and dry canal groups, although the chi-square test was not statistically significant (p = 0.071). CONCLUSIONS: Intracanal conditions significantly influenced the apex locator accuracy. Normal saline provided the most accurate measurements, whereas the dry conditions showed greater variability. Maintaining a moist canal environment may enhance clinical reliability.

Schlagwörter

Stichwörter der Autor:innen

electronic apex locatornormal salineroot canal irrigantsodium hypochloriteworking length

Autor:innen und Institutionen

  • Department of Conservative Dentistry and Endodontics, Rama Dental College Hospital and Research Center, Kanpur, IND.
  • Department of Conservative Dentistry and Endodontics, Swami Devi Dyal Hospital and Dental College, Panchkula, IND.
  • Department of Conservative Dentistry and Endodontics, College of Dental Science and Hospital, Indore, IND.
  • Department of Conservative Dentistry and Endodontics, Uttaranchal Dental and Medical Research Institute, Dehradun, IND.
  • Department of Conservative Dentistry and Endodontics, Smiline Dental Hospital, Hyderabad, IND.
  • Department of Conservative Dentistry and Endodontics, Kanti Devi Dental College and Hospital, Mathura, IND.

Zitieren

APA

Ahmad, M. Z., Thakur, D., Ghosh, M., Chaudhary, R., Reddy, A., & Gupta, T. (2026). Comparative Evaluation of the Accuracy of an Electronic Apex Locator Using Two Different Canal Conditions: An In Vitro Study. Cureus. https://doi.org/10.7759/cureus.108889

Vancouver

Ahmad MZ, Thakur D, Ghosh M, Chaudhary R, Reddy A, Gupta T. Comparative Evaluation of the Accuracy of an Electronic Apex Locator Using Two Different Canal Conditions: An In Vitro Study. Cureus. 2026. doi:10.7759/cureus.108889

BibTeX
@article{Ahmad2026,
  author = {Ahmad, Mohd Zeeshan and Thakur, Divyangana and Ghosh, Megha and Chaudhary, Ritika and Reddy, Anuradha and Gupta, Twinkle},
  title = {Comparative Evaluation of the Accuracy of an Electronic Apex Locator Using Two Different Canal Conditions: An In Vitro Study},
  journal = {Cureus},
  year = {2026},
  doi = {10.7759/cureus.108889}
}
Kostenlos starten →