EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparative Accuracy of Three Electronic Apex Locators and Two Digital Radiographic Systems in Working Length Determination: An In Vitro Study

Javeriya Shahid, Imran Khan, Jawad Ali Shah, Tabinda Shan, Samia Rasool, Zahra Zubair

Indus Journal of Bioscience Research · 30.05.2025 · 3 (5) · 1404-1408

DOI: 10.70749/ijbr.v3i5.1966 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indus Journal of Bioscience Research, online erschienen am 30.05.2025. Verfasst von Javeriya Shahid und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Determining working length is essential for successful root canal treatment. This study compared the accuracy of three types of Electronic Apex Locators (EALs) and two types of Digital radiography systems in determining canal working lengths against the actual working length.

Methods

This comparative experimental study included 300 canals from extracted anterior and posterior teeth. Actual working length was determined by advancing a 10-K file to the apical end and visualizing it under loupe magnification. The teeth were embedded in alginate along with the X-ray sensor and the clip of the electronic apex locator. The working lengths were recorded with two X-ray systems (SOREDEX DIAGORA Optime and Carestream) and three EALs (J. Morita DentaPort ZX, Woodpex V, and Bomedent iRoot Pro Apex). A Wilcoxon signed-rank test was used to compare the measurements. The mean absolute error groups were also compared; a p-value

Zitieren

APA

Shahid, J., Khan, I., Shah, J. A., Shan, T., Rasool, S., & Zubair, Z. (2025). Comparative Accuracy of Three Electronic Apex Locators and Two Digital Radiographic Systems in Working Length Determination: An In Vitro Study. Indus Journal of Bioscience Research, 3(5), 1404-1408. https://doi.org/10.70749/ijbr.v3i5.1966

Vancouver

Shahid J, Khan I, Shah JA, Shan T, Rasool S, Zubair Z. Comparative Accuracy of Three Electronic Apex Locators and Two Digital Radiographic Systems in Working Length Determination: An In Vitro Study. Indus Journal of Bioscience Research. 2025;3(5):1404-1408. doi:10.70749/ijbr.v3i5.1966

BibTeX
@article{Shahid2025,
  author = {Shahid, Javeriya and Khan, Imran and Shah, Jawad Ali and Shan, Tabinda and Rasool, Samia and Zubair, Zahra},
  title = {Comparative Accuracy of Three Electronic Apex Locators and Two Digital Radiographic Systems in Working Length Determination: An In Vitro Study},
  journal = {Indus Journal of Bioscience Research},
  year = {2025},
  volume = {3},
  number = {5},
  pages = {1404--1408},
  doi = {10.70749/ijbr.v3i5.1966}
}
Kostenlos starten →